409-2908
24
of 32
Rev A
3. Perform all steps of general reassembly procedure (Paragraph 8.3) to reassemble tool.
8.13. Wire Funnel Replacement
1. Disconnect tool from factory air supply.
2. Remove four screws holding top cover to tool. Slide front of top cover to right from under wire funnel lever
pin to release top cover assembly from tool.
3. Drive pin (Item 41, Figure 32) out from right side of top cover to remove wire funnel; use care not to lose
spring.
4. Insert replacement wire funnel in slot in top cover, ensure that spring is in position in retaining hole, and
drive pin through wire funnel from left side of top cover (pin flush with left side of top cover).
5. Replace top cover assembly and tighten the four holding screws. Check wire funnel operation before
connecting tool to factory air supply.
6. Check operation of tool to determine if hold down adjustment is required (Paragraph 8.7).
8.14. Air Line Filters and Lubricators
The use of air line filters and lubricators is recommended with TE pneumatic tooling. This equipment is not
manufactured or sold by TE. The position of the recommended equipment is shown in Figure 31.
Figure 31
9. STORAGE
If the tool is not used, it must be stored by taking the following precautions:
• Store the tool indoors.
• Grease unpainted parts.
• Protect this tool from knocks or stresses.
• Protect the tool from high levels of humidity and from big temperature changes.
• Prevent the tool from coming into contact with corrosive substances.
10. DECOMMISSIONING
In compliance with the regulations in force in the country where the tool is used, the user must make sure that
waste produced during operation is correctly disposed of. Disposal of lubricants and parts removed must be
carried out in compliance with the standards in force in the country where the tool is used.
11. REPLACEMENT AND REPAIR
Customer-replaceable parts are listed in Figures 32 and 33. Parts other than those listed should be replaced by
TE to ensure quality and reliability. Order replacement parts through your local TE Representative, or call 1-800-
526-5142, or send a facsimile of your purchase order to 717-986-7605, or write to:
CUSTOMER SERVICE (038-035)
TYCO ELECTRONICS CORPORATION
PO BOX 3608
HARRISBURG PA 17105-3608
For customer repair service, call 1-800-526-5136.
12. REVISION SUMMARY
•
Updated document to meet CE standards and current TE format and standards.
Filter
Lubricator
TE
Tools
Install air regulator between the
filter and lubricator if shop air
supply exceeds 655 kPa [95 psi].
NOTE
i