SRSE-MA-2NO SAFETY RELAY MODULE
INDUSTRIAL/SRSE-MA-2NO SAFETY RELAY MODULE
3
This symbol indicates an important personal safety warning. Failure to comply with the warning may result
in very high risk for exposed personnel.
This symbol indicates an important warning.
OVERVIEW
The SRSE-MA-2NO safety relay is able to monitor two inputs coming from safety gate, safety guard or similar
(two channels electromechanical safety switch).
The SRSE-MA-2NO module main features are the following:
•
2 inputs are able to monitor two external electromechanical safety switches
•
2 N.O. outputs with guided contact safety relays
•
Manual operation mode with Monitored Restart
•
1 system status PNP output
•
1 external contactors feedback input
OPERATING MODE
MANUAL MODE
With
manual mode
, the outputs of the safety relay are activated only if the safety relay inputs (terminals 7, 8)
are both active and after sending the RESTART signal to the relay using the push-button or by means of a
specific command on the RESTART input (terminal 4) (please refer to
section).
Figure 1