RBK-X1 CE
PN 2234800-2 / -4 / -6
Page 38 Rev B Apr 2020
Problem
Possible Cause
Verification
Solution
Heating chamber moves forward
and returns immediately to the
Home position.
‘
Load
’
proximity
sensor permanently
'OFF' or defective.
May be positioned
incorrectly.
Check that the
‘
Load
’
sensor internal LED
is illuminated
.
Adjusting sensor
position. Replace
sensor if necessary.
Pressing the cycle buttons will reset the sen-
sor control but will move the chamber to the
Home position if not correct.
Machine overheats. Covers and
guards are warmer than normal.
Switch off
procedure not
being observed.
Switch off at I/O
switch
Fan will continue to
run until 190°C and
then switch off.
Blue stand-by led will
be lit.
Ensure correct
switching procedures
are carried out.
Cooling fan failure
Check fan function.
Replace fan.
No action when shift on quick
process buttons.
Keypad Lock Mode
‘
KEYL
’
selected on.
Check in parameter
for KEYL settings.
Reset KEYL to OFF
RS232 Communication does not
function.
‘
REMT
’
not on.
Check parameters.
Set
‘
REMT
’
to ON.
RS232 cable not
connected to
welder or
Processor.
Check
interconnecting
cable.
Reconnect...
External device
setting error
Check data format is
comply with RBK-X1
(refer to 3.8.2) by port
testing software.
Make sure transfer
data between RBK-
X1 and external
device on data
format
Содержание RBK-X1 CE
Страница 45: ...RBK X1 CE PN 2234800 2 4 6 Page 44 Rev B Apr 2020 Right Cover Securing Screws 7X...
Страница 51: ...RBK X1 CE PN 2234800 2 4 6 Page 50 Rev B Apr 2020 6 Schematic Diagram...
Страница 52: ...RBK X1 CE PN 2234800 2 4 6 Page 51 Rev B Apr 2020...
Страница 53: ...RBK X1 CE PN 2234800 2 4 6 Page 52 Rev B Apr 2020...
Страница 55: ...RBK X1 CE PN 2234800 2 4 6 Page 54 Rev B Apr 2020 9 Declaration of conformity of CE...