RBK-X1 CE
PN 2234800-2 / -4 / -6
Page 22 Rev B Apr 2020
3.7
Manual Calibration
1. Set tool to 500°C and 15 second cycle time.
2. Connect UHI probe to a calibrated meter.
3. Carry out 3 calibration readings (cool UHI to 23°C between each cycle).
Calculate average value.
4. Compare measured value (average) with desired value of 130°C ± 5°C.
If below, adjust OFST to desired value - measured value (negative result).
If above, adjust OFST to measured value - desired value (positive result).
5. Wait 25 minutes for temperature to stabilise.
6. Repeat 3 (and 4 if necessary).
7. After OFST has been adjusted correctly it is necessary to wait 15 minutes for temperature to stabilise prior
to normal use.
It is recommended to carry out an auto calibration after manual calibration in order to remove the
Cal!
Message in the display panel.
Note: If this does not disappear it is necessary to replace the heater set and auto calibrate.