Routine Maintenance
The RBK- X1 requires only the minimum of maintenance. However, the following checks must be
carried out on a weekly basis:
1. Check the cooling fan is operating correctly and air is flowing through the rear vent panel.
2. Remove front cover. Check for correct clearance (a minimum of 75mm clear space) and
obstructions.
3. Wire Grippers. Check visually for correct operation and signs of wear.
4. Manual Release. Check that manual release levers operate freely.
5. Clean the tube hot melt left on the heating element and loading position.