Rev 3
7
of 7
4.
QUALIFICATION
QSFP_DD pc board connectors are Recognized by Underwriters Laboratories Inc. (UL) in File E28476.
5.
TOOLING
No tooling is required for manual placement of the connectors onto the pc board.
For automatic machine placement, the robotic equipment must have a true position accuracy tolerance
sufficient to properly locate the connector. This includes gripper and fixture tolerances as well as
equipment repeatability. It must use the connector datum surfaces given on the customer drawing to
ensure reliable placement.
6.
VISUAL AID
Figure 6. Visual Aid
The illustration above shows a typical application of 152-position Stacked QSFP_DD pc board connector.
This illustration should be used by production personnel to ensure a correctly applied product.
Applications which do not appear correct should be inspected using the information in the preceding
pages of this specification and in the instructional material shipped with the product or tooling.
EACH SOLDER FILLET
MUST BE EVENLY FORMED
WITH NO VISIBLE CRACKS
RIGHT-ANGLE CONNECTOR
HOUSING MUST NOT BE
DEFORMED OR DAMAGED
IN ANY WAY
EACH CONTACT SOLDER TINE
MUST NOT BE DEFORMED
AND MUST BE SEATED ON
CIRCUIT PAD