Move the forked sleeve (1) to the right (arrow), so that the red marker (2) appears.
This lifts out the chamber fixation from its functional position.
At once the gripper is getting blocked against pinching.
Fig. 64: Blocking the gripper
Make sure that the red marker appears.
Only in this position the gripper is blocked against pinching!
Repeat the positioning of the stuffer below the insulation displacement termination to be handled by
means of the guidance, the locking of the chamber fixation by means of the forked sleeve, the
feeding of the insulated wire, the pinching and loosening of the gripper as well as the release of the
chamber fixation for all chambers to be provided with a wire
After finishing the process press down the press bar and pull off the connector.
Do not tension the wires due to damaging the contacting!
Fig. 65: Removing the connector