412-10100
Rev A
9
of 74
The specifications for the CQM II are listed in Table 1, Table 2, and Table 3.
Table 1: Electrical
Operating voltage (DC power supply)
100-240 VAC, 50/60 Hz, 1.5 amps (max.)
Host and DAQ (data acquisition) operating voltage
24 VDC
Table 2: Ambient operating environment
Temperature
5-40° C [40-104° F]
Relative humidity
< 95% non-condensing
Table 3: Sensors
Force strain gage
Wheatstone bridge force sensor
Force piezo
ICP low impedance quartz force sensor
Displacement
Analog hall effect sensor
Linear quadrature encoder (5Vdc, 2 micron)
Inputs/outputs: Four programmable outputs for machine interface.
NOTE
Use the AC power cord that is appropriate with your countr
y’
s power system (typically included with the system). Ensure that
the cord is plugged into a circuit that has over-current protection of no greater than 15-20 amps (country dependent).
To best use the machine and manual, complete the following steps.
1. Open the package.
2. Inspect the contents.
3. Install the machine (using drawings and 408 instructions).
4. Configure the machine as described in section 3.3.
5. Set up the machine for production operation.