412-10100
Rev A
26
of 74
4.6
Crimp Height
If Crimp Height is selected, touch the Crimp Height arrow or the right arrow icon to move to the next task.
Enter the specific Crimp Height and Tolerance for the part by touching the appropriate box. For the entry of
tolerance, if the tolerance from the manufacturer is +/-
0.002” inches enter 0.002” inches
Select the Update Control Limit radio button to turn on the feature that tells the monitor to automatically
calculate a control limit for the part during production. The Default Control Limit initializes to 0.0015 inches and
will automatically change once 30 production crimps have occurred.
The user can specify their own control limit if they do not want to have one updated for them. The control limit is
also important with the autoadjust feature on some G-terminators. When the average crimp height of three
consecutive PASS crimps is outside the Control Limit the autoadjust motor on the G-terminator will make an
adjustment to bring the crimp height back within the control limit range.
Figure 20: Crimp Height
Touch the next Sensitivity arrow or the right arrow icon to move to the next task.