background image

408-2681

2 of 5

Rev C

Figure 3

5. Crimp the contact by squeezing the tool handles. 
Then tighten screws of the hold-down device and 
contact locator. If the contact crimp is straight and 
the wire barrel has not been damaged, the tool is 
ready to use.

If the tool has been preset for wire size 10 AWG -

the smallest wire size-no further adjustment is 

necessary, even though wire size 8 or 6 AWG is to 

be terminated; the setting for wire size 10 will also 

accommodate wire size 8 or 6. However, if the anvil 

die is not set for wire size 10 and wire size 8 or 6 is 

desired, then the anvil die should be set to the 

appropriate wire size of either 8 or 6.

6. If the wire size marking is positioned for a wire 
size other than desired, depress the anvil die 
spring-loaded indexing pin and rotate the anvil die 
until the desired size appears. Then release the 
indexing pin and allow locator pin to snap into the 
hole which locks the anvil die in place for the 
desired size.

7. Open the tool head, and position the contact in 
the nest, locating the outer end of the wire barrel 
(wire-entry end) so that it extends from the nest 
area between 0.76 to1.02 mm [.030 to .040 in.] as 
shown in Figure 4.

Figure 4

8. Close tool head just enough to retain the contact; 
then insert the wire into the wire barrel, making sure 
the wire does not extend beyond the wire barrel. 
See Figure 5.

Figure 5

9. Slowly squeeze the handles, making sure contact 
remains aligned properly in the nest. It may be 
necessary to open the handles slightly, allowing the 
contact to be re-adjusted in the nest. Continue to 
squeeze the handles to complete the crimp.

4. CRIMP INSPECTION

Inspected the crimped contact according to Figure 6. 
Poorly crimped contacts can be avoided through 
careful use of these instructions.

For a detailed inspection requirements, refer to 

Application Specification 114-6032.

Figure 6

5. MAINTENANCE AND INSPECTION

5.1. Daily Maintenance

It is recommended that each operator of the tool be 
made aware of-and responsible for-the following steps 
of daily maintenance:

1. Remove dust, moisture, and other contaminants 
with a clean brush, or a soft, lint-free cloth. DO NOT 
use objects that could damage the tool.

Wire Conductor Flush 

with or Recessed 

Slightly in Wire Barrel

Wire Insulation Does 

Not Enter Contact 

Wire Barrel

Contact Must Retain 

Proper Position in 

Nest During Entire 

Crimping Procedure

Configuration 

of Nest

Wire Barrel

NOTE

i

Hold-Down Device and Contact Locator Screws

Torque of Contact

Fits in Slot

Wire Does Not Extend into 

Contact Transition Area

Wire Barrel Extends 

0.76-1.02 [.030-.040] 

from Nest

NOTE

i

Wire Strands Visible Here - 

Insulation Must Not Enter 

Wire Barrel

Wire Strands Must Not 

Extend Beyond this Area 

or Above Wire Barrel

Crimp Inspection

Contact Must be 

Straight in this Area

Отзывы: