5.
CRIMP INSPECTION
Inspect crimped terminals and splices by checking the features described in Figures 7 and 8. Use ONLY the
terminals and splices
that meet the conditions shown in the “ACCEPT” column. Unacceptable terminals and
splices (depicted in the “REJECT” column can be avoided through careful use of the crimping procedure and
by performing regularly scheduled die maintenance.