b. Shut Height Fine Adjustment
(1) Loosen the fine adjust head clamping screw.
(2) Turn the adjust ring clockwise to increase shut height or counter-clockwise to decrease shut
height.
(3) Retighten the fine adjust head clamping screw.
NOTE
Each line on the
fine adjust head scale corresponds to a shut height adjustment increment of 0.02mm[.0008”]
.
Figure 7
c. Hand Lever Angle Adjustment
(1) Loosen the screw to release the handle spline from the split clamp.
(2) Adjust the angle of the hand lever as needed.
(3) Retighten the screw to clamp the handle spline in the split clamp.
Figure 8