background image

408-2331

2 of 6

Rev C

Figure 2

2. Insert conductor into contact wire barrel until 
contact butts against cable dielectric, and place 
contact in tool head as shown in Figure 2.

3. Push cable IN to hold center contact against and 
perpendicular to locator/stop. MAKE SURE that the 
raised area on the contact wire barrel is located ON 
the crimping die for proper termination.

4. Close tool handles FULLY until ratchet releases 
to complete crimp. Note that once the ratchet is 
engaged, handles cannot be opened until they have 
been fully closed.

3.2. Crimping the Ferrule

Assemble the connector body over the crimped 
contact as described in connector instructions and 
proceed as follows:

1. Place connector assembly in tool as shown in 
Figure 3. MAKE SURE that the ferrule assembled 
on the cable is on the upper crimping die, and that 
the shoulder on the connector rests against the die, 
as shown.

2. Close handles until CERTI-CRIMP hand crimping 
tool ratchet control releases to complete crimp.

Figure 3

4. MAINTENANCE AND INSPECTION PROCEDURE

TE Connectivity recommends that a maintenance and 
inspection program be performed periodically to 
ensure dependable and uniform terminations. Though 
recommendations call for at least one inspection a 
month, frequency of inspection depends on:

TOOL NO.

220015

CONTACT TYPE

LONG (Min)

Short (Max)

-1

22.02 [.867]

17.45 [.687]

-2

21.36 [.841]

16.81 [.662]

-3

22.02 [.867]

17.45 [.687]

-4

26.04 [1.025]

21.51 [.847]

-6

22.02 [.867]

17.45 [.687]

Отзывы: