408-1542
Rev T
4
of 8
Figure 4
Periodic Inspection
1. The tool should be immersed (handles partially closed) in a reliable commercial degreasing compound
to remove accumulated dirt, grease, and foreign matter.
2. Close tool handles until ratchet releases and then allow them to open freely. If they do not open
quickly and fully, the spring is defective and must be replaced. See Section 6, REPLACEMENT AND
REPAIR.
3. Inspect head assembly for worn, cracked, or broken jaws. Refer to Figure 5. If damage is evident,
return the tool to TE for evaluation and repair. See Section 6, REPLACEMENT AND REPAIR.