22
Disabled
. Other options include:
•
Entry
: Entry reader.
•
Exit
: Exit reader.
•
Entry / Exit
: Entry and exit reader.
Manage maximum access per group:
Enable limitations of the number of entries through a reader
based on access group.
Activate on valid presentation:
Activate the anti-passback in collaboration with the door sense i.e.
when the user presents a valid credential and opens the door. In order for this functionality to work the
Door properties
must be configured to have the
Door sense
property set. By default, this is set to
Disabled
. Note: This changes the events generated by the unit. When a valid credential is presented
to the unit, “User awaiting validation” event is generated first. When the user opens the door (within
the lock delay), the Access Granted” event is then generated.
Deduct from presentations
: This enables the amount of times a credential has operated a reader. The
credential must also be configured with the
Number of presentations
option ticked and an initial
value set. Options include:
•
Do not count, do not test:
Perform no validation checks
•
Test:
Test the number of times the credential has been used on the reader without counting.
Block the user if the amount is 0. When the limit has been reached, the event “Access limit
reached” is generated.
•
Test and count
: Test the number of times a credential has been used on the reader and
deduct from the count, then block the credential if the access count amount is 0. New event
is generated with this option “Access Count”. The event includes the amount of counts left for
that credential. When the limit has been reached, the event “Access limit reached” is
generated.
•
Daily Count
: Deduct from the count a maximum of 1 per day. The credential can be
presented to the reader numerous times in a single day and only 1 would be deducted from
the count.
Enable interlocking mode:
Enable man trap.
Keypad readers
When using a reader with a keypad, select
Reader with keypad
from the
Reader type
drop down. A
new section will be displayed to allow further configuration.
Keypad type:
Select the required output type. Available options: - Wiegand 4 bit (send out each key
press as a 4 bit data) or Wiegand 26 bit (send out a number of key presses as 1 26 bit data length). Set
Wiegand 4 bit option for TDSi Keypad readers.
Keypad lock:
Select whether you would like the keypad to be disabled after a number of incorrect
PIN entries (Maximum of 10). This option is set to “Never lock the keypad” by default.
Release door (timing
based on lock time)
Save
settings
Back to
main page
Set reader name
Enable reader
These sections are available
with all reader types
Содержание GARDiS Series
Страница 1: ...GARDiS Controller Embedded Web Server User Manual UM0121 Issue 3...
Страница 4: ...Timed Anti passback 46 Troubleshooting 47 Restoring from backup 47...
Страница 8: ...8 Step 3 Click GARDiS Master Unit from menu Step 4 Enter the required IP settings Step 5 Click Save...
Страница 14: ...14 Step 14 Enter details for the new user i e last name...
Страница 19: ...19 Once selected click open This will initiate the restore process A message box will display once completed...
Страница 25: ...25...
Страница 30: ...30 This will set the selected schedule within the dropdown...
Страница 34: ...34 Step 1 Step 2 Step 3 Step 4...
Страница 49: ...49 Because everyone deserves peace of mind...