Installation
DIGIgarde PLUS User Guide
Last Change
Copyright
©
2012 TDSi
13 May, 2016
Page 15
2.3.3
2.3.3
2.3.3
2.3.3
Power connection
Power connection
Power connection
Power connection
You can power the unit directly using a DC supply or by using PoE (Power over
Ethernet).
CAUTION! Allow a period of 10 minutes before reapplying power if supplies
are switched between PoE and a DC supply of vice versa.
It is strongly recommended that if the reader is connected to an access
control unit it is also powered from this to prevent damage resulting from
any difference in earth potentials.
Using a DC power supply
Using a DC power supply
Using a DC power supply
Using a DC power supply
To power the unit, connect red and black wires labelled
Power
to a power supply
rated at 10 to 14 VDC and capable of supplying a current of 500mA.
Label
Wire Colour
Signal
Description
Power
Black
0V
Power GND
Red
+12V
Power Input
Using PoE
Using PoE
Using PoE
Using PoE
Connect the DIGIgarde PLUS to a PoE-enabled network device such as an
Ethernet switch using the RJ45 connector and an appropriate CAT5 (or higher)
cable. You can also ‘inject’ power into the network cable using a midspan power
supply or PoE injector.
2.3.4
2.3.4
2.3.4
2.3.4
Wiegand
Wiegand
Wiegand
Wiegand/Magnetic Clock Data to a compatible ACU
/Magnetic Clock Data to a compatible ACU
/Magnetic Clock Data to a compatible ACU
/Magnetic Clock Data to a compatible ACU
Connect the wire
WD0-OUT
on the reader to
Data 0
on the access control unit and
the wire
WD1-OUT
on the reader to
Data 1
on the access control unit.
Label
Wire Colour
Signal
Description
WG OUT
Yellow
WD0-OUT
Wiegand Output, Data 0
White
WD1-OUT
Wiegand Output, Data 1
Black
GND
Wiegand GND
Blue
LED
LED
Содержание DIGIgarde PLUS