- 7 -
TDK-Lambda
ZWS10
・
15B
・
30B Series
Instruction Manual
5
.
Mounting Directions
5-1. Output Derating according to the Mounting Directions.
Recommended standard mounting method is (A). Method (B)-(F) are also possible. Refer to the output derating below.
Load(%) of derating curve indicates output power.
5-2. Output Derating vs Ambient temperature
Make sure that the specified temperature range is maintained. Operate the unit out of the specified derating curve may trigger OTP (IC
integrated). When OTP trigger, the output will be shut down. To reset OTP, remove the input of power supply for a few minutes, wait until
the unit cool down, and then re-input.
▥
CONVECTION COOLING
ZWS10B
ZWS15B