PH
PH
B-319
・All specifications are subject to change without notice.
PH75S280 Specifications
PH
75S280
0
20
40
60
80
100
−
20
0
20
40
60
85
80
100
Baseplate Temperature (℃)
Load
(
%
)
型名 PH75S280
Derating Curve
ITEMS/UNITS
MODEL
PH75S280-3.3 PH75S280-5 PH75S280-12 PH75S280-15 PH75S280-24 PH75S280-28
Input
Voltage Range
V
DC200 - 400
Efficiency (typ)
(*1)
%
72
81
83
84
85
Current (typ)
(*1) A
0.25
0.33
0.32
Output
Nominal Voltage
VDC
3.3
5
12
15
24
28
Maximum Current
A
15
6.3
5
3.2
2.7
Maximum Power
W
49.5
75
75.6
75
76.8
75.6
Voltage Setting Accuracy (*1)
%
±
1
Maximum Line Regulation (*2) mV
20
48
60
96
112
Maximum Load Regulation (*3) mV
40
96
120
192
224
Temperature Coefficient
0.02%/
℃
Maximum Ripple & Noise (*9) mVp-p
100
150
240
280
Voltage Adjustable Range (*8)
+10%, -10% (At 280VDC Input)
Function
Over Current Protection (*4)
105 - 150%
Over Voltage Protection (*5)
165 - 240%
125 - 145%
Remote Sensing
―――――
Remote ON/OFF Control (*8)
Possible (SHORT: ON OPEN: OFF)
Parallel Operation
―――――
Series Operation
(*8)
Possible
Environment
Operating Temperature (*6)
℃
-20 to +85 (Baseplate) Ambient temperature min = -20
Storage Temperature
℃
-40
℃
to + 85
℃
Operating Humidity
%
RH
30 ~ 95 (No dewdrop)
Storage Humidity
%
RH
10 ~ 95 (No dewdrop)
Vibration
At no operating, 10-55Hz amplitude (sweep for 1min)
0.825mm constant (maximum 49.0m/s²) X, Y, Z 1h each
Shock
196.1m/s² (In package)
Cooling
(*7)
Conduction cooled
Isolation
Withstand Voltage
Input-Baseplate : 2.5kVAC, Input-Output : 3kVAC (20mA) for 1min,
Output-Baseplate : 500VDC for 1min
Isolation Resistance
More than 100M
Ω
at 25
℃
and 70%RH Output-Baseplate...500VDC
Standards
Safety Standards
Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1
Mechanical
Weight (typ)
g
100
Size (W x H x D)
mm
41 x 12.7 x 86 (Refer to outline drawing)
(*1) At 280VDC and maximum output current.
(*2) 200 - 400 VDC, constant load.
(*3) No load - full load, constant input voltage.
(*4) Constant current limiting with automatic recovery.
(*5) Inverter shutdown method, manual reset.
(*6) Ratings - Refer to derating curve below.
- Load(%) is percent of maximum output current.
(*7) Heatsink has to be chosen according to instruction manual.
(*8) Refer to instruction manual.
(*9) External components are needed for operation.
(Refer to basic connection and instruction manual.)