PH
PH
B-311
・All specifications are subject to change without notice.
PH300F48
PH300F48 Specifications
PH
300F48
0
20
40
60
80
100
−20
0
20
40
60
80
100
Baseplate Temperature
(℃)
Load
(%)
85
型名 PH300F48
Derating Curve
ITEMS/UNITS
MODEL PH300F48-2 PH300F48-3 PH300F48-5 PH300F48-12 PH300F48-15 PH300F48-24 PH300F48-28
Input
Voltage Range
V
DC36 - 76
Efficiency (typ)
(*1)
%
68
73
82
85
86
89
90
Current (typ)
(*1) A
3.68
5.14
7.62
7.35
7.26
7.16
7
Output
Nominal Voltage
VDC
2
3
5
12
15
24
28
Maximum Current
A
60
25
20
12.6
10.8
Maximum Power
W
120
180
300
302.4
Voltage Setting Accuracy (*1)
%
±
1
Maximum Line Regulation (*2) mV
20
48
60
96
112
Maximum Load Regulation (*3) mV
40
96
120
192
224
Temperature Coefficient
0.02%/
℃
Maximum Ripple & Noise (*9) mVp-p
100
150
240
280
Voltage Adjustable Range (*10)
±
20%
+20%, -60%
Function
Over Current Protection (*4)
105% - 140%
Over Voltage Protection (*5)
165% - 240%
125% - 145%
Remote Sensing
(*8)
Possible
Remote ON/OFF Control (*8)
Possible (SHORT: ON OPEN: OFF)
Parallel Operation
(*8)
Possible
Series Operation
(*8)
Possible
I.O.G. Signal
(*8)
Possible (Open collector output)
Environment
Operating Temperature (*6)
℃
-20 to 85
(
Baseplate) Ambient temperature MIN=20
℃
Storage Temperature
℃
-40 to 85
Operating Humidity
%
RH
30 - 95 (No dewdrop)
Storage Humidity
%
RH
10 - 95 (No dewdrop)
Vibration
At no operating, 10-55Hz (sweep for 1min)
Amplitude 0.825mm constant (maximum 49.0m/s²) X, Y, Z 1 h each
Shock
196.1m/s² (In package)
Cooling
(*7)
Conduction cooled
Isolation
Withstand Voltage
Input-Baseplate : 2.5kVAC, Input-Output : 3kVAC(20mA) for 1min
Output-Baseplate : 500VDC(100mA) for 1min
Isolation Resistance
More than 100M
Ω
at 25
℃
and 70%RH Output-Baseplate...500VDC
Standards Safety Standards
Approved by UL60950-1, CSA C22.2 No.60950-1, EN60950-1
Mechanical
Weight (typ)
g
250
Size (W x H x D)
mm
146 x 12.7 x 86 (Refer to outline drawing)
(*1) At 48VDC and maximum output current.
(*2) 36 - 76VDC, constant load.
(*3) No load - full load, constant input voltage.
(*4) Constant current limiting with automatic recovery.
(*5) Inverter shutdown method, manual reset.
(*6) Ratings - Refer to derating curve below.
- Load(%) is percent of maximum output current.
(*7) Heatsink has to be chosen according to instruction manual.
(*8) Refer to instruction manual.
(*9) External capacitor is required.
(Refer to instruction manual.)
(*10) At 48VDC input. (Refer to instruction manual.)