1
TDK-Lambda
LS 200 Series
INSTRUCTION MANUAL
1. Terminal Explanation
Please pay extra attention to the wiring. Incorrect connection may cause damage the power supply.
z
When connecting input and output wiring, input AC-Line should be OFF.
z
Input wiring and output wiring shall be separated, otherwise noise susceptibility of power supply unit
will be weak.
z
The protective earth (PE) must be connected to the instrument chassis and the chassis of this power
supply unit.
z
Remote sensing lines shall be twisted or use shielded wire.
z
Remote ON/OFF control lines shall be twisted or use shielded wire.
1-1.
Front Panel Explanation
(1)
L : Input terminal
Live line (Fuse in line)
(2)
N : Input terminal Neutral line
(3)
FG
: Functional Ground
(4)
- V : - Output terminal
(5)
+V : + Output terminal
(6)
Output voltage adjustable trimmer
(7)
Output monitoring indicator
(Green LED : ON)
(8)