38
83503001 Rev G
WARNING
Shorting the output may expose the user to hazardous
voltages. Observe proper safety procedures.
3.8.7. Foldback Check
Refer to Section 5.5 for explanation of the FOLD function prior to performing the
procedure below.
a) Ensure that the Output Voltage is set to approx. 10% of the unit rating.
b) Adjust the CURRENT encoder to set the Output Current setting to approx. 10% of
the unit rating.
c) Momentarily press the FOLD button. Ensure that the FOLD LED illuminates. The
Output Voltage remains unchanged.
d) Short the output terminals momentarily (approx. 0.5 sec.). Ensure that the Output
Voltage falls to zero, the VOLT display shows “Fb” and the ALARM LED blinks.
e) Press the FOLD button again to cancel the protection. The Output Voltage remains
zero.
f)
Press the OUT button. Ensure that the Output Voltage returns to its last setting.
g) Turn the output off by pressing the OUT button. Ensure that the VOLT display
shows “OFF”.
3.8.8. Address Setting
a) Press and hold the REM/LOC button for approx. 3 sec. The VOLT display will show
the communication port address.
b) Using the VOLT adjust encoder, check that the address can be set within the range
of 0 to 30.
3.8.9. Baud Rate Setting (RS-232 and RS-485 only)
a) Press and hold the REM/LOC button for approx. 3 sec. The CURRENT display will
show the communication port Baud Rate.
b) Using The CURRENT adjust encoder, check that the Baud Rate can be set to
1200, 2400, 4800, 9600 and 19200.
3.9.
Connecting the Load
WARNING
Turn Off the AC input power before making or changing any rear
panel connection. Ensure that all connections are securely tightened
before applying power. There is a potential shock hazard when using
a power supply with a rated output greater than 40V.
3.9.1. Load Wiring
The following considerations should be made to select wiring for connecting the load to
the power supply:
Current carrying capacity of the wire (refer to Section 3.9.2)
Insulation rating of the wire should be at least equivalent to the maximum output
voltage of the power supply.
Maximum wire length and voltage drop (refer to Section 3.9.2)
Noise and impedance effects of the load wiring (refer to Section 3.9.4).