4-4. Over Voltage Protection (OVP)

The OVP function (Inverter shut down method, manual reset type) is provided. Please refer to its specification for OVP 
operating range. When OVP triggers, the output will be shut down. To reset OVP, remove the input of power supply for a few 
minutes, and then re-input. In addition, the setting value of OVP is fixed and not adjustable. Pay attention not to apply higher 
voltage externally to the output terminal to avoid unit failure. In case of inductive load, put protective diode in series to the 
output power line.

4-5. Over Current Protection (OCP)

The OCP is hiccup mode with automatic recovery. The outputs will be automatically recovered when the overload condition 
is canceled. 
OCP function operates when the output current exceeds 105% of maximum DC output current of specification. Never operate 
the unit under over current or shorted conditions for more than 30seconds, which may leads damage or insulation failure. OCP 
setting is fixed and not to be adjusted externally. 

4-6. Output Ripple & Noise

The standard specification for maximum ripple value is measured according to measurement circuit specified as below. When 
load lines are longer, ripple will becomes larger. In this case, electrolytic capacitor, film capacitor, etc. might be necessary to 
use across the load terminal. The output ripple cannot be measured accurately if the probe ground lead of oscilloscope is too 
long. 
A circuit reducing light load input power consumption is built in this model. When output current is within 0-35% of rated 
load, the internal switch element is intermittent operated, and the switching loss is decreased. The specification of the Ripple 
& Noise changes by this intermittent operation. The dynamic load response characteristic changes by this intermittent 
operation too. Different input voltage and dynamic load condition has different dynamic load response characteristic. Please 
contact us for details.

4-7. Series Operation

For series operation, either method (A) or (B) is possible.

Method (A)

Method (B)

(*1)Please select a bypass diode with maximum forward current rating more than output load current. And maximum reverse 
voltage must withstand each power supply output voltage. 

5/14

Load

C1

150mm

C2

Coaxial Cable

1.5m 50

R1

C3

Bandwidth : 20MHz 

Power

Supply

+V

-V

C1 : 0.1uF   Cap., Film
C2 : 100uF  Cap., Elect
C3 : 4700pF Cap., Ceramic
R1 : 50

Oscilloscope

-V

-V

+V

+V

+

-

Load

Power

Supply

Power

Supply

(*1)

-V

-V

+V

+V

+

+

-

-

Load

Load

Power

Supply

Power

Supply

Содержание CUS100MB Series

Страница 1: ...ould be kept within specifications otherwise the product will be damaged Do not operate and store this product in an environment where condensation might occur In such case waterproof treatment is nec...

Страница 2: ...eeClause16 IEC UL60601 1 2 TheseproductsareNOTsuitableforuseinthepresenceofflammableanaestheticmixtures with air or with oxygen or withnitrous oxide 3 Theseproductsareclassedasordinary equipment accor...

Страница 3: ...tion Output Terminal OutputTerminal V ADJ Output voltage adjusttrimmer Theoutput voltageriseswhenthetrimmeristurnedclockwise Mountinghole holediameter 3 5mm Thishole isusedforsupporttheunit 3 Terminal...

Страница 4: ...creased Take note when the output voltage is increased excessively over voltage protection OVP function may be triggered and voltage will be shut down Furthermore when increasing the output voltage re...

Страница 5: ...rding to measurement circuit specified as below When load lines are longer ripple will becomes larger In this case electrolytic capacitor film capacitor etc might be necessary to use across the load t...

Страница 6: ...ed voltage must be gradually increased from zero to the testing value and then gradually decreased for shut down When timer is used the power supply may be damaged by high impulse voltage at timer swi...

Страница 7: ...for models except CUS100MB A Recommended standard mounting direction is A Mounting direction B E are also possible A Standard mounting B C D E 5 1 2 Mounting directions for CUS100MB A Recommended stan...

Страница 8: ...2 12V 15V 18V model 3 24V Model 8 14 Convection and Force Air Cooling Mounting A B C D E Ta C Load 20 50 100 70 50 Convection Cooling Force Air Cooling Mounting A B C D E Mounting A B C D E Ta C Load...

Страница 9: ...C D E Convection Cooling Force Air Cooling Mounting A B C D E Mounting A B C D E Ta C Load Load 100 50 70 40 Ta C 20 30 100 20 50 50 80 70 Convection Cooling Force Air Cooling Mounting A B C D E Mount...

Страница 10: ...ing components will not exceed max temperature in the table Absolutetemperature Temperaturerise Ambient temperature 5 2 2 Output derating for CUS100MB A CUS100MB A is convection cooling type Makesuret...

Страница 11: ...uirement or more space depend on safety requirement If the space is not enough the specification of isolation and withstand voltage will notbesatisfied More space may be required in the surrounding of...

Страница 12: ...ied More space may be required in the surrounding of power supply and the upper area of components for effective cooling depends on the application conditions All equipment ideally should be mounted i...

Страница 13: ...nal filtering may be required depends on application and installation methods Pleaserefertofollowingapplicationnotes whichmayhelptoimproveEMCperformance 1 The output load line and input line shall be...

Страница 14: ...ies but not limited to the following 1 Average operating temperature ambient temperature of the power supply unit is under 40 2 3 years warranty base on 24 hours day operation at 100 load Please refer...

Отзывы: