TDK-Lambda CUS100MB Series Скачать руководство пользователя страница 1

INSTRUCTION MANUAL

CUS100MB

TDK-Lambda

<Page>

BEFORE USING THE POWER SUPPLY UNIT

Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before 
using this product. Incorrect usage could lead to an electrical shock, damage to the unit or a fire hazard.

DANGER

Never use this product in locations where flammable gas or ignitable substances are present. There are risks of igniting these 
substances and exploding by an arcing.

WARNING

Do not touch this product or its internal components while circuit is live, or shortly after shut down. There may be high voltage

or high temperature present and you may receive an electric shock or burn.

When this product is operating, keep your hands and face away from it as you may be injured by an unexpected situation.
Do not make unauthorized changes to this product, otherwise you may receive an electric shock and void your warranty.
Do not drop or insert anything into this product. It might cause a failure, fire and electric shock.
Do not use this product under unusual condition such as emission of smoke or abnormal smell and sound etc. It might lead to 

fire and electric shock. In such cases, please contact us. Do not attempt repair by yourself, as it is dangerous for the user.

Do not operate these products in the presence of condensation. It might lead fire and electric shock.

CAUTION

This power supply is designed and manufactured for use within an end product such that it is accessible to SERVICE

ENGINEERS only.

Confirm connections to input/output terminals are correct as indicated in the instruction manual before switching on.
Input voltage, Output current, Output power, ambient temperature and ambient humidity should be kept within specifications, 

otherwise the product will be damaged.

Do not operate and store this product in an environment where condensation might occur. In such case, waterproof treatment is

necessary.

Do not use this product in environment with a strong electromagnetic field, corrosive gas or conductive substances.
For applications, which require very high reliability, it is necessary to provide a fail-safe mechanism in the end equipment.
Do not inject abnormal voltages into the output of this product. The injection of reverse voltage or over voltage exceeding 

nominal output voltage into the output terminal might cause damage to internal components.

Never operate the product under over current or short-circuit conditions, or outside its specified Input Voltage Range. 

Insulation failure, smoking, burning or other damage may occur.

This product contains a printed circuit board utilizing surface mounted devices. PCB stress such as bending, twisting etc. could

cause damage. Therefore, please handle with care.

When handling this product, hold the board edge and take care not to touch the component side. When installing this product 

in apparatus or equipment, mount it on spacers.

This product has used Power Thermistor to protect the circuit from Inrush Current. Frequent repetition of input on/off might 

cause damage to internal components because of generating surge current.

Breaking of internal fuse is considered internal failure. In such cases, please contact us.
The information in this document is subject to change without prior notice. Please refer to the latest version of the data sheet, 

etc., for the most up-to date specifications of the product.

Double pole / neutral fusing.

No part of this document may be copied or reproduced in any form without prior written consent of TDK-Lambda.

Note : CE MARKING

CE marking, when applied to this series products, indicates compliance with the Low Voltage Directive.

1/14

CA833-04-01A

Содержание CUS100MB Series

Страница 1: ...ould be kept within specifications otherwise the product will be damaged Do not operate and store this product in an environment where condensation might occur In such case waterproof treatment is nec...

Страница 2: ...eeClause16 IEC UL60601 1 2 TheseproductsareNOTsuitableforuseinthepresenceofflammableanaestheticmixtures with air or with oxygen or withnitrous oxide 3 Theseproductsareclassedasordinary equipment accor...

Страница 3: ...tion Output Terminal OutputTerminal V ADJ Output voltage adjusttrimmer Theoutput voltageriseswhenthetrimmeristurnedclockwise Mountinghole holediameter 3 5mm Thishole isusedforsupporttheunit 3 Terminal...

Страница 4: ...creased Take note when the output voltage is increased excessively over voltage protection OVP function may be triggered and voltage will be shut down Furthermore when increasing the output voltage re...

Страница 5: ...rding to measurement circuit specified as below When load lines are longer ripple will becomes larger In this case electrolytic capacitor film capacitor etc might be necessary to use across the load t...

Страница 6: ...ed voltage must be gradually increased from zero to the testing value and then gradually decreased for shut down When timer is used the power supply may be damaged by high impulse voltage at timer swi...

Страница 7: ...for models except CUS100MB A Recommended standard mounting direction is A Mounting direction B E are also possible A Standard mounting B C D E 5 1 2 Mounting directions for CUS100MB A Recommended stan...

Страница 8: ...2 12V 15V 18V model 3 24V Model 8 14 Convection and Force Air Cooling Mounting A B C D E Ta C Load 20 50 100 70 50 Convection Cooling Force Air Cooling Mounting A B C D E Mounting A B C D E Ta C Load...

Страница 9: ...C D E Convection Cooling Force Air Cooling Mounting A B C D E Mounting A B C D E Ta C Load Load 100 50 70 40 Ta C 20 30 100 20 50 50 80 70 Convection Cooling Force Air Cooling Mounting A B C D E Mount...

Страница 10: ...ing components will not exceed max temperature in the table Absolutetemperature Temperaturerise Ambient temperature 5 2 2 Output derating for CUS100MB A CUS100MB A is convection cooling type Makesuret...

Страница 11: ...uirement or more space depend on safety requirement If the space is not enough the specification of isolation and withstand voltage will notbesatisfied More space may be required in the surrounding of...

Страница 12: ...ied More space may be required in the surrounding of power supply and the upper area of components for effective cooling depends on the application conditions All equipment ideally should be mounted i...

Страница 13: ...nal filtering may be required depends on application and installation methods Pleaserefertofollowingapplicationnotes whichmayhelptoimproveEMCperformance 1 The output load line and input line shall be...

Страница 14: ...ies but not limited to the following 1 Average operating temperature ambient temperature of the power supply unit is under 40 2 3 years warranty base on 24 hours day operation at 100 load Please refer...

Отзывы: