9. Altitude

CUS100MB is safety approved for operation at below altitude.
- Up to 5000m by IEC60950-1 clearance requirement.
- Up to 5000m by IEC60601-1 clearance requirement.
Thermal evaluation should be considered for products operating at elevated altitudes above 2000m. 

10. Warranty Condition

These products are under warranty for 3 years from the date of shipment. During the warranty period, TDK-Lambda will, 
either repair or replace products prove to be defective. 

3 years warranty applies but not limited to the following.
(1) Average operating temperature (ambient temperature of the power supply unit)is under 40

.   

(2) 3 years warranty base on 24 hours/day operation at 100% load.
Please refer to electrolytic capacitor life time from reliability data for various application conditions such as mounting, load 
derating, operating ambient temperature etc.   
Customer system design could be improved with better electrolytic capacitor life time by selecting proper application method. 

Following cases are not covered by warranty.
(1)   Improper usage like dropping products, applying shock and defects from operation exceeding specification of the units.
(2)   Defects resulting from natural disaster (fire, flood etc.).
(3)   Unauthorized modifications or repair.

Содержание CUS100MB Series

Страница 1: ...ould be kept within specifications otherwise the product will be damaged Do not operate and store this product in an environment where condensation might occur In such case waterproof treatment is nec...

Страница 2: ...eeClause16 IEC UL60601 1 2 TheseproductsareNOTsuitableforuseinthepresenceofflammableanaestheticmixtures with air or with oxygen or withnitrous oxide 3 Theseproductsareclassedasordinary equipment accor...

Страница 3: ...tion Output Terminal OutputTerminal V ADJ Output voltage adjusttrimmer Theoutput voltageriseswhenthetrimmeristurnedclockwise Mountinghole holediameter 3 5mm Thishole isusedforsupporttheunit 3 Terminal...

Страница 4: ...creased Take note when the output voltage is increased excessively over voltage protection OVP function may be triggered and voltage will be shut down Furthermore when increasing the output voltage re...

Страница 5: ...rding to measurement circuit specified as below When load lines are longer ripple will becomes larger In this case electrolytic capacitor film capacitor etc might be necessary to use across the load t...

Страница 6: ...ed voltage must be gradually increased from zero to the testing value and then gradually decreased for shut down When timer is used the power supply may be damaged by high impulse voltage at timer swi...

Страница 7: ...for models except CUS100MB A Recommended standard mounting direction is A Mounting direction B E are also possible A Standard mounting B C D E 5 1 2 Mounting directions for CUS100MB A Recommended stan...

Страница 8: ...2 12V 15V 18V model 3 24V Model 8 14 Convection and Force Air Cooling Mounting A B C D E Ta C Load 20 50 100 70 50 Convection Cooling Force Air Cooling Mounting A B C D E Mounting A B C D E Ta C Load...

Страница 9: ...C D E Convection Cooling Force Air Cooling Mounting A B C D E Mounting A B C D E Ta C Load Load 100 50 70 40 Ta C 20 30 100 20 50 50 80 70 Convection Cooling Force Air Cooling Mounting A B C D E Mount...

Страница 10: ...ing components will not exceed max temperature in the table Absolutetemperature Temperaturerise Ambient temperature 5 2 2 Output derating for CUS100MB A CUS100MB A is convection cooling type Makesuret...

Страница 11: ...uirement or more space depend on safety requirement If the space is not enough the specification of isolation and withstand voltage will notbesatisfied More space may be required in the surrounding of...

Страница 12: ...ied More space may be required in the surrounding of power supply and the upper area of components for effective cooling depends on the application conditions All equipment ideally should be mounted i...

Страница 13: ...nal filtering may be required depends on application and installation methods Pleaserefertofollowingapplicationnotes whichmayhelptoimproveEMCperformance 1 The output load line and input line shall be...

Страница 14: ...ies but not limited to the following 1 Average operating temperature ambient temperature of the power supply unit is under 40 2 3 years warranty base on 24 hours day operation at 100 load Please refer...

Отзывы: