User manual
9-3
DSC/DSCT Series
CON.
DESCRIPTION
FIELD
DEFAULT
Notes
c
25 Parallel bit to LS2
0(OPEN) 1(CLOSED)
1
c
26 Ramp inclusion
0(excluded) 1(included)
0
c
27 Stop with or without minimum
speed
0(disabled) 1(enabled)
1
c
28 Stop on limit switches with or
without ramp
0(with) 1(without)
0
c
29 Software drive consent
0(alarm) 1(no alarm)
1
c
30 Reset alarms
0(disabled) 1(reset)
0
c
31 External current limit enable (in
series to external enable)
0(disabled) 1(enabled)
0
c
32 Enable torque input
0(disabled) 1(enabled)
0
c
33 relative or absolute speed data
0(relative) 1(absolute)
0
c
34 Motor thermal devices causes
drive block
0(do not stop) 1(stop)
0
c
35 Pos./Speed
(0 = Speed. 1 = Pos.)
0
r
c
36 Start Pos. 1
(0 = not active 1 = active)
0
c
37 Start Pos. 2
(0 = not active 1 = active)
0
c
38 Zero search direction
(0=CCW,LS2 1 = CW,LS1)
0
n
c
39 relative/absolute positions
(0=relative 1=absolute)
0
c
40 SW Zero search command
(0 = not active 1 = active)
0
c
41 Reset default values
0(disabled) 1(reset)
0
n
c
42 Reset EEPROM values
0(disabled) 1(reset)
0
n
c
43 EEPROM writing
0(disabled) 1(reset)
0
n
c
44 Resolver phase auto-tuning
command
0(disabled) 1(perform)
0
r
c
45 Current regulator auto-tuning
command
0(disabled) 1(perform)
0
r
Bold
C
indicates the most used parameters that had to be setted in a new installation.
9.3.
MAGNITUDES WHICH MAY BE DISPLAYED
DISPLAYS
FIELD
d
1 External speed reference %
±100.0%
d
2 Speed ref. before the ramp %
±100.0%
d
3 Speed ref. after the ramp %
±100.0%
d
4 Speed feedback %
±100.0%
d
5 Motor speed in r.p.m. %
0
÷
19000
d
6 Integral part of the speed regulator %
±100.0%
d
7 Value of the external torque demand signal %
±100.0%
d
8 External current limit %
0
÷
100.0%
d
9 Last current limit CW %
0
÷
100.0%
d
10 Last current limit CCW %
0
÷
(-100.0)%
d
11 Current demand %
±100.0%
d
12 Voltage on the power circuit (V)
0
÷
999
d
13 Actual position (encoder pulse)
mod. 20000
d
14 Resolver reading (encoder pulse)
±
1/2 pulses c11
ALARMS
STATE (H=0N L=OFF)
A
1 Internal supply alarm
L-H
A
2 RAM, EEPROM alarm
L-H
A
3 Power alarm
L-H
A
4 Radiator thermal switch alarm
L-H
A
5 Motor thermal switch alarm
L-H
A
6 Motor in thermal overload
L-H
A
7 Resolver failure
L-H
A
8 External alarm
L-H