User manual
7-5
DSC/DSCT Series
7.2.
LOGIC OUTPUTS CONFIGURATION
C07
L.O.1
L.O.
1
7
8
0
16
C08
L.O.2
L.O.
2
11
12
0
16
3
J1
AVAILABLE CHOICES
THE THICK LINE INDICATES DEFAULT
PROGRAMMING
DRIVE READY
0
AVAILABLE OUTPUT FUNCTIONS
MOTOR THERMAL ALARM
1
SPEED GREATER THAN MINIMUM
2
DRIVE ON-LINE
3
CW/CCW
4
SPEED REGULATOR SATURATION
5
RAMP END
6
SPEED IN RANGE
7
CURRENT IN RANGE
8
MOTOR BLOCKED
9
STOP IN POSITION
10
RAMP ACTIVE
11
DECELERATION AREA
12
STOP IN POS. 1
13
STOP IN POS.2
14
15
SPEED < P41 AND
POSITION ERROR < 1
16
Maximum current 30mA/24Vcc
In the version DSCT (3x380Vac) the logical output
C07
is not programmable and remains then configurated
as signal of
drive ready
.
The maximum current is about 30mA.
7.3.
ANALOGIC OUTPUT CONFIGURATION
With the connection
c13
it is possible to read on the programmable analog output at the terminal J2-3 some
of the internal values; in particular are possible the following scheme connections:
A.P.O.1
3
100
Ω
Ω
Ω
Ω
c13
1
11
J2
AVAILABLE CHOICES
CURRENT REQUEST
11
THE THICK LINE INDICATES THE
DEFAULT PROGRAMMING
3
EXTERNAL TORQUE REFERENCE
7
SPEED FEEDBACK
4
INTEGRAL PART OF THE SPEED
REGULATOR
6
REFERENCE AFTER THE RAMP
3
REFERENCE BEFORE THE RAMP
2
EXTERNAL SPEED REFERENCE
1
AVAILABLE OUTPUT FUNCTIONS
output
±±±±
10V/2mA