                                                                                                                        MA00001E00 V_1.1

 

 

F.11 

IP_ADDR_03 

Anybus IP Address 03 

255 

 

F.12 

SUBNET_MASK_00 

Anybus Subnet Mask 00 

255 

255 

 

F.13 

SUBNET_MASK_01 

Anybus Subnet Mask 01 

255 

255 

 

F.14 

SUBNET_MASK_02 

Anybus Subnet Mask 02 

255 

255 

 

F.15 

SUBNET_MASK_03 

Anybus Subnet Mask 03 

255 

 

F.16 

GATEWAY_00 

Anybus Gateway 00 

255 

 

F.17 

GATEWAY_01 

Anybus Gateway 01 

255 

 

F.18 

GATEWAY_02 

Anybus Gateway 02 

255 

 

F.19 

GATEWAY_03 

Anybus Gateway 03 

255 

 

F.20 DHCP 

Anybus 

DHCP  0 

 

F.21 

ANYBUS_EN 

Anybus module enabled 

0000 

FFFF 

(1)

 HEX 

F.22 

ANYBUS_STATE 

Anybus module state 

0000 

FFFF 

(1)

 HEX 

Notes: (1) - read only 

Parameters related to data exchange mapping of Profibus DP and Anybus CC 

Name

 

OPD Explorer name

 

OPD Explorer description

 

Min

 

Max

 

Default

 

UM

 

F.23 

MAP_ERROR_CODE 

Mapping Error Code 

0000 

FFFF 

(1)

 HEX 

F.24 

MAP_ERROR_OBJ 

Mapping Error Object 

0000 

FFFF 

(1)

 HEX 

F.25 

RX0_INDEX 

Receive Object0 Index 

0000 

FFFF 

0000 

HEX 

F.26 RX0_SUB_INDEX Receive 

Object0 

Sub-Index 

0000 FFFF 

0000 

HEX 

F.27 

RX1_INDEX 

Receive Object1 Index 

0000 

FFFF 

0000 

HEX 

F.28 RX1_SUB_INDEX Receive 

Object1 

Sub-Index 

0000 FFFF 

0000 

HEX 

F.29 

RX2_INDEX 

Receive Object2 Index 

0000 

FFFF 

0000 

HEX 

F.30 RX2_SUB_INDEX Receive 

Object2 

Sub-Index 

0000 FFFF 

0000 

HEX 

F.31 

RX3_INDEX 

Receive Object3 Index 

0000 

FFFF 

0000 

HEX 

F.32 RX3_SUB_INDEX Receive 

Object3 

Sub-Index 

0000 FFFF 

0000 

HEX 

F.33 

RX4_INDEX 

Receive Object4 Index 

0000 

FFFF 

0000 

HEX 

F.34 RX4_SUB_INDEX Receive 

Object4 

Sub-Index 

0000 FFFF 

0000 

HEX 

F.35 

RX5_INDEX 

Receive Object5 Index 

0000 

FFFF 

0000 

HEX 

F.36 RX5_SUB_INDEX Receive 

Object5 

Sub-Index 

0000 FFFF 

0000 

HEX 

F.37 

RX6_INDEX 

Receive Object6 Index 

0000 

FFFF 

0000 

HEX 

F.38 RX6_SUB_INDEX Receive 

Object6 

Sub-Index 

0000 FFFF 

0000 

HEX 

F.39 

RX7_INDEX 

Receive Object7 Index 

0000 

FFFF 

0000 

HEX 

F.40 RX7_SUB_INDEX Receive 

Object7 

Sub-Index 

0000 FFFF 

0000 

HEX 

F.41 

RX8_INDEX 

Receive Object8 Index 

0000 

FFFF 

0000 

HEX 

F.42 RX8_SUB_INDEX Receive 

Object8 

Sub-Index 

0000 FFFF 

0000 

HEX 

F.43 

RX9_INDEX 

Receive Object9 Index 

0000 

FFFF 

0000 

HEX 

F.44 RX9_SUB_INDEX Receive 

Object9 

Sub-Index 

0000 FFFF 

0000 

HEX 

F.45 

TX0_INDEX 

Transmit Object0 Index 

0000 

FFFF 

0000 

HEX 

Содержание 374T000600V

Страница 1: ...Cod MA00001E00 V_1 1 Accessories Tde Macno User s Manual Remote Keypad ...

Страница 2: ......

Страница 3: ...DRAWINGS 3 5 ORDERING INFORMATION 4 6 CONNECTIONS 4 7 INTERFACE ADAPTERS 6 8 PANEL MOUNTING 7 9 OPERATIONS 7 9 1 BEYOND LEGACY DISPLAY LIMITATIONS 8 9 2 RUN SIGNALLING LED 8 9 3 MENU LOC local parameters 8 9 4 MENU FLB fieldbus parameters 9 9 5 EXTENSION OF MENU APP 11 9 6 ADDITIONAL CUSTOM KEYS AND LEDS 12 ...

Страница 4: ...drive that then can be used to connect with a controller for process automation or to a PC for configuring and monitoring by OPDExplorer In this case the connection between drive and remote keypad is limited just to point to point not multidrop 2 SPECIFICATIONS Power supply Voltage 5 30 Vdc reversed polarity protected to dedicated 3 poles connector on the back side Current 200 mA overall power sup...

Страница 5: ...wnload of drive firmware Core and Application under development access to the stored data from PC via RS485 interface under development 3 ENVIRONMENTAL SPECIFICATIONS Operating temperature 10 50 C Storage temperature 20 70 C Relative humidity 10 90 non condensing Shock operation 10 to 25 Hz X Y Z direction 2G 30 minutes CE FCC complies with EN 61000 4 4 EN 61000 6 Plastic enclosure case meets prot...

Страница 6: ...x Rx 2 3 internally shorted 3 TX_RX 4 5 Term positive polarization termination 6 TX_RX RS485 half duplex inverting signal Tx Rx 6 7 internally shorted 7 TX_RX 8 9 Term negative polarization termination Please notice that the remote keypad RS485 interface is HALF DUPLEX so only 3 wires signals TX_RX TX_RX 0V can be connected between devices Pins 2 and 3 are internally shortened and so also pins 6 a...

Страница 7: ...cable with twisted pairs min AWG 22 is also recommended To enhance EMI noise immunity when remote keypad is used with mini OPD EXP it is also recommended to connect the communication cable shield to ground using the PE bar of the drive Also some level of noise reduction can be achieved using a ferrite core like FairRite 0431178281 or better winding some turns of cable on toroid like Vacuumshmelze ...

Страница 8: ...atisfied In these cases the main RS485 of the drive can t be used anymore to connect the remote keypad as there can be only one active Modbus master present on the bus in order to avoid bus contentions The remote keypad can be configured by param to be idle not active on the bus so it is possible to physically connect the keypad and another master device on the same bus without conflicts but this ...

Страница 9: ...tomation controller on the main interface and use 2nd interface to connect to OPD Explorer for commissioning keep in mind address and bitrate limitation 8 PANEL MOUNTING Follow these steps to mount the remote keypad on a switchboard front panel using the optional kit 1 remove the 2 screws from the backside of remote keypad 2 apply the sealing gasket to the channel presents along the side of the ke...

Страница 10: ... digits follows the parameter letter So using the same examples as before P100 is displayed as and P199 is displayed as For the same reason the keypad integraded into the drive can t manage parameters with index greather than 199 it can t be represented at all while with the remote keypad can show indexes up to 999 This is useful in the managing of the extension of APP menu with the access to appl...

Страница 11: ...o show and edit raw 16bit data value Notice that all parameters in FLB menu are not protected by any key nor by run status so they can be changed at any time Also be aware that some parameter related to the configuration of fieldbuses take effect only at power on so changes become effective only after saving and cycling the power supply Parameters related to configuration of Profibus DP and Anybus...

Страница 12: ...FFFF 0000 HEX F 27 RX1_INDEX Receive Object1 Index 0000 FFFF 0000 HEX F 28 RX1_SUB_INDEX Receive Object1 Sub Index 0000 FFFF 0000 HEX F 29 RX2_INDEX Receive Object2 Index 0000 FFFF 0000 HEX F 30 RX2_SUB_INDEX Receive Object2 Sub Index 0000 FFFF 0000 HEX F 31 RX3_INDEX Receive Object3 Index 0000 FFFF 0000 HEX F 32 RX3_SUB_INDEX Receive Object3 Sub Index 0000 FFFF 0000 HEX F 33 RX4_INDEX Receive Obj...

Страница 13: ... to E99 that often in the documentation and also in OPD Explorer are referred as parameters from P200 up to P299 That s enough for almost all the applications but some ones need to define more parameters and data For this purpose the drive supply a specific memory area that till now was accessible only by OPD Explorer In the remote keypad the APP menu has been extended in order to allow access to ...

Страница 14: ...itional keys referred as F1 to F3 and 4 additional signalling leds referred as L1 to L4 up to 2 more keys and leds can be added on request The colour of the leds are L1 yellow L2 yellow L3 yellow L4 green These keys and leds aren t used by the operator interface so no functions and meanings are normally associated with They are available for direct management by the drive application and so can be...

Страница 15: ......

Страница 16: ...Via dell Oreficeria 41 36100 Vicenza Italy Tel 39 0444 343555 Fax 39 0444 343509 www tdemacno com s p a tecnologie digitali elettroniche ...

Отзывы: