background image

6280 TouchCenter Keypads         

 

Installation Guide 

Ê800-07600ÀpŠ

800-07600   7/11  Rev. A

 

For Online Support visit: http://www.security.honeywell.com/hsc/resources/MyWebTech/ 

 

 

                       

General Information                                                                     6280 TouchCenter 

This guide provides information on installing and setting up Honeywell's 
6280 TouchCenter Keypads. The 6280 Series graphical touch-screen 
keypads are Advanced User Interface (AUI) devices, which combine 
control of your security system, multi-media and premises lighting.  

 

Compatibility: 

 For a list of alarm systems that the TouchCenter can 

interface with, refer to the Compatibility Table in this document. 

 
Wiring 
IMPORTANT

: If you power the TouchCenter from your panel’s auxiliary 

power output, check your panel’s Installation and Setup Guide and verify 
that this device and others do not exceed your panel’s auxiliary power 
output capability; if it does, a supplementary power supply is needed. 

 
Word List 

The 6280 TouchCenter can annunciate a series of words. You must use 
the vocabulary list in your alarm panel instructions for actual words that 
may be annunciated; refer to the Word List in this document. 

 

 

Front Panel LEDs  

6280-001-V0

FLASHING

 – The system contains new

message(s) for the User.

OFF

 – No new messages.

RESET BUTTON

Press to unlock keypad

ON

 – System is armed.

OFF

 – System is not armed.

ARMED (RED) LED

READY (GREEN) LED

ON

 – System is disarmed and ready to arm.

OFF

 – System is armed or disarmed but not

ready. If disarmed, faults or troubles are present.

MESSAGE (YELLOW) LED

SD/SDHC CARD Slot

 

 

Mounting the TouchCenter 

This Keypad is for indoor use only and should be mounted at a comfortable viewing level.  Avoid mounting in areas of 
high condensation such as bathrooms or in locations where bright light or sunlight shines directly on the screen. The 
TouchCenter can be mounted with or without the mounting plate. Use the center securing screw for European installation. 

 

The 6280 complies with the European Standard 
EN50131 and is designed to prevent unauthorized use.

Standard Mounting with mounting plate:

  

1. Select a mounting location.  

2.  

Detach the mounting plate by sliding downward.   

3.  Use the mounting plate to mark the location of the mounting 

holes on the mounting surface and check for level.   

4. Locate the mounting plate over the mounting surface such that 

the wire/cable access openings are aligned while passing the 
wires/cable through the case back.

  

***

Go to “Wiring the TouchCenter” and complete wiring***

 

5. Secure the mounting plate to mounting surface using 4 screws 

(supplied)

.  

6. Slide TouchCenter onto mounting plate.

 

6280-006-V0

WALL

SURFACE

WALL
MOUNTING

PLATE
(OPTIONAL)

MOUNTING

SCREWS (4)

(TYP)

 

Mounting without mounting plate:  

1.  Select a mounting location.  
2.  Detach the mounting plate by sliding downward and 
discard.

 

3.

 

Use the template (provided in the carton) to mark the 

location of the mounting screws and the cut-out for the 
TouchCenter assembly on the mounting location. Check 
for level.  
4. Install 4 screws (supplied)

 

in the mounting surface 

leaving screw heads 1/8” above the mounting surface.  
5.  Locate the case back over the mounting surface such 
that the opening is aligned with the wire/cable access 
opening on the mounting surface while passing the 
wires/cable through the opening in the case back.  
**

Go to “Wiring the TouchCenter” and complete wiring

 

6.  Mount TouchCenter by sliding onto the screw heads. 

4 - 3/4"

3 - 9/16"

800-08831    5/11    Re

v.A

CUT

-OUT LOCA

TION

DRILL 3/16" DIA.

 HOLES

4 PLA

CES

Ê800-00831u

Š

6280 SERIES CASE B

ACK MOUNTING 

TEMPLA

TE

DRILL 3/16" DIA.

 HOLE

6280-016-V0

MOUNTING

SCREWS

INSTALLED

1/8” ABOVE

SURFACE

TEMPLATE

WALL

SURFACE

 

 

Mounting (European Installations) using a center securing 
screw: 

1. Detach case front by removing the two bottom screws. Gently pull 
up using a screwdriver if necessary and pry apart. Lift off cover.  
2. Mount the TouchCenter in its final location, (see “Standard 
Mounting” or “Mounting without the mounting plate”) install center 
securing screw (supplied) and tighten to mounting surface. 
3. Replace the case front and secure using the two bottom screws. 

 
 
 
 

6280-015-V0

INSTALL TAMPER

SCREW

DETACH CASE FRONT

BY REMOVING SCREWS (2)

AND LIFT UP

CASE

FRONT

CASE

BACK

 

 

Wiring the TouchCenter 

6280-014-V0

BLACK

POWER FROM SUPPLEMENTARY

POWER SUPPLY IF USED

6280

RED 

BLACK

GREEN

YELLOW

CONTROL

TERMINAL STRIP

SUPPLEMENTARY

+12 VDC

POWER SUPPLY

P/N AD12612

BLACK (GND)

RED (+12VDC) 

GREEN
(DATA TO
CONTROL)

YELLOW
(DATA FROM
CONTROL)

CONTROL

TERMINAL STRIP

AUX

DATA

IN

DATA

OUT

AUX

DATA

IN

DATA

OUT

AUX AUX

Y

G

 

UL

 

Use a UL Listed, battery-backed supply for UL installations. The battery supplies power to these keypads in case of AC power loss. The battery-backed power 
supply should have enough power to supply the keypads with the UL required minimum standby power time. 

IMPORTANT: 

Keypads powered from supplies that do not have a backup battery do not function if AC power is lost. Make sure to power at least one keypad in 

each partition from the control’s auxiliary power output or UL Listed battery backed up power supply. 

 

IMPORTANT:

  When the TouchCenter is powered from an auxiliary power supply, always apply power to the control panel first and then the TouchCenter. Failure to observe 

this sequence results in improper operation of the TouchCenter and may result in an ECP Error indication. 

Connect the wires to the TouchCenter terminal block as shown. 

  Connect the TouchCenter in parallel with keypads and other peripheral devices using the keypad data (ECP) bus.  

  If the TouchCenter is used as the primary system keypad, maximum wire run length is 150 feet. 

  If more than one keypad is wired to one run, then the maximum lengths must be divided by the number of keypads on the run.  (e.g., the maximum length is 75 feet if two keypads are 

wired on a #22 gauge run). 

Note:

 Unshielded 4-conductor cable is recommended for the power/data wire. 

 

Mechanical Specifications:    

 

Width: 8 inches (203.2mm)  
Height: 5-1/2 inches (139.7mm) 
Depth:1-3/8 inches (35mm)        

Electrical Specifications:    

 

Backlight OFF, Sound OFF

 

12V, 140mA 

 

Backlight ON, Sound OFF 

12V, 205mA  

Backlight ON, Sound ON 

12V, 270mA 

Operating Environment: 

Humidity  

93% RH, no condensation 

Temperature:

 

Operating  

 14˚ F to 131˚ F / -10˚ C to 55˚ C  

Shipping / Storage 

-40˚ F to 158˚ F / -40˚C to 70˚C  

Wire Gauge:           

Length 

#22 gauge 

150 feet 

#20 gauge 

240 feet 

#18 gauge 

350 feet 

#16 gauge 

550 feet 

 

Initial Setup 

Programming the Control Panel 

The TouchCenter is not fully operational unless its address in the control panel 

has been enabled (set as an alpha console) AUI type device, and assigned to a 
partition (where applicable).  

We recommend that you use either a standard alpha keypad or the TouchCenter in 

Console Emulation Mode when programming the control panel. When in the 

Console Mode, the TouchCenter emulates an alpha keypad and the programming 

of the panel is performed following the procedures provided in your panel’s 

Installation & Setup Guide. 

Note:

 When programming your control panel, if you change the zone types for your 

emergency zones you may disable the emergency icons in the TouchCenter. The 

emergency icons in the TouchCenter are active for zone types 06 and 07 (Panic 

icon), 08 (Medical icon), and 09 (Fire icon). Additionally, the Medical icon is also 

compatible with a zone type 15 (24-Hour Medical) for panels that contain this zone 

type. 

The TouchCenter should not be assigned as a Master Console. If the TouchCenter 
is assigned as a Master Console, partitions must be controlled from the Partition 

screen or by using the Console Emulation Mode. 

TouchCenter Initialization 

When initially powered, the screen displays the boot sequence and the "Set ECP 

Address" screen is displayed. If the system is incorporating only one TouchCenter, 

leave the address set to 1 and touch 

Apply

.  The boot-up process continues until  

completion. If there are to be additional TouchCenter units in the system, after 

enabling addresses in the control panel using an alpha-keypad, power-up each 

TouchCenter one at a time, and set its address to one of the addresses you 
enabled in the control panel.    

Note:

 If the top of the screen is displaying ECP Error, the TouchCenter ECP 

Address is not valid for the panel that it is connected to. To change the ECP 

Address, enter the default code of  “4140” to advance to the next screen.  

Note:

 4140 is the TouchCenter default installer code before connecting to a 

control panel. Once connected to a control panel, use the panel’s installer code. 

Change the ECP Address on the unit, using the Up/Down arrows and then touch 

apply to accept the address and reset the TouchCenter. Once communication has 

been restored, then use the standard panel installer code for all installer 

functions. Refer to “ECP Setup” section. 

Time/Date Setup 

If not already set from the panel, set the current time and date. Refer to 

“Time/Date Setup” section.  

NIGHT Setup

 

The TouchCenter is defaulted to arm the system in the STAY INSTANT mode 

when arming the system using the NIGHT icon.  

Select the arming mode to be activated when the 

NIGHT

 icon is touched on the 

"Arming" screen, refer to “Night Setup” section. 

 

* Refer to the instructions on the following pages to customize your TouchCenter. 

Summary of Contents for 6280 Series

Page 1: ... AUX DATA IN DATA OUT AUX AUX Y G UL Use a UL Listed battery backed supply for UL installations The battery supplies power to these keypads in case of AC power loss The battery backed power supply should have enough power to supply the keypads with the UL required minimum standby power time IMPORTANT Keypads powered from supplies that do not have a backup battery do not function if AC power is los...

Page 2: ...ll through the list of pictures and highlight the file you want to be displayed on the keypad screen 2 Touch the Set Wallpaper icon view your selection from the Home screen NOTE When viewing wallpaper displays the Home screen icons can be minimized by touching the Minimize Home icon Touch the Maximize Home icon to maximize Home screen icons The Picture feature allows you to set up and view photos ...

Page 3: ...Code Device Events Notes 1 Touch the Device Events icon 2 To view a record of events in a history log touch the up down arrow to scroll The control panel must be programmed to record various system events in installer programming mode Panel Configuration Notes 1 Touch the Panel Config icon If you select OK the TouchCenter resets and the panel configuration is downloaded from the panel into the Tou...

Page 4: ...ng screen Note that some displays on the TouchCenter may not have enough space to display the whole name of a partition When this occurs the display shows as many characters as possible starting at the beginning of the partition name We recommend that the partition name be kept to a maximum of 7 characters to ensure the H which indicates the home partition may be seen this is set at the panel Outp...

Reviews: