Table common switch combinations (DIP switch 1-9)

Value

Combination 

Value

Combination 

10

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

150

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

20

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

200

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

25

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

250

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

50

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

400

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

100

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

500

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

Table display value (factory preset, can be changed by software)

Display value

Display

Scale

Manual mode

Save mode

60 mV DC 
scaled
(shunt)

Ampere
DC

Upper scale 
caption

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

J1

J6

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

J1

J6

50 mV DC 
scaled
(shunt)

Ampere
DC

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

J1

J6

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

J1

J6

0-20 mA DC
scaled 
(analogue signal)

Process

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

J1

J6

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

J1

J6

4-20 mA DC 
scaled
(analogue signal)

Process

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

J1

J6

ON

  1     2     3     4     5     6     7     8     9   1 0   1 1   1 2

J1

J6

----- 

6

 -----

Содержание Digalox DPM72-PP

Страница 1: ...device hazardous voltages must not be connected to the device The device must not be used as the only protective device or protective shutdown Read instruction manual carefully before operating the d...

Страница 2: ...ion display style pointer tachometer bar graph and more splash image thresholds for alarm output hysteresis and more Recorded measurement values can be read and a continuous transmission of the actual...

Страница 3: ...Digalox Load Shunt U 50 V max 200 mV Ilow Ihigh Uhigh Ulow L N Legend Current source e g active sensor or sensor with voltage supply WARNING The device may only be operated in one of the connection o...

Страница 4: ...display value or the one that is selected by the jumpers J4 J6 or the DIP switches 11 12 respectively see table display value Scaling via DIP switches If the scaling to represent the correct display v...

Страница 5: ...lues repeat steps 3 8 until all required display values are configured The time base does not need to be set again as it is used for all display values 10 In operation the display values can be change...

Страница 6: ...2 3 4 5 6 7 8 9 1 0 1 1 1 2 Table display value factory preset can be changed by software Display value Display Scale Manual mode Save mode 60 mV DC scaled shunt Ampere DC Upper scale caption ON 1 2 3...

Страница 7: ...sec When first opening and closing J1 the current time base is displayed For each subsequent opening and closing the time base changes to the next setting In order to save the setting permanently DIP...

Страница 8: ...mpere 20 mA AC DC max 100 mA 10 500 Hz Accuracy ampere 0 5 true RMS Internal resistance ampere 6 2 Measuring value update 5 Hz 32 kHz sampling rate Recording of measurement 36 seconds to 14 days 180 i...

Отзывы: