During the first 12 months from the date of purchase and subject to the conditions hereinafter set forth, TCW 
Technologies, LLC. (TCW) will repair or replace to the original user or consumer any portion of your new TCW product 
which proves defective due to defective materials or workmanship of TCW.  Contact TCW Technologies for warranty 
service. TCW shall have and possess the sole right and option to determine whether to repair or replace defective 
equipment, parts or components. Damage due to equipment, environment or conditions beyond the control of TCW 
Technologies are NOT COVERED BY THIS WARRANTY. 
 
  
LABOR, COSTS: TCW shall IN NO EVENT be responsible or liable for the cost of field labor or other charges incurred 
by any customer in removing and/or reaffixing any TCW product, part or component thereof. 
 
THIS WARRANTY WILL NOT APPLY: (a) to defects or malfunctions resulting from failure to properly install, 
operate or maintain the unit in accordance with printed instructions provided; (b) to failures resulting from abuse, 
accident, or negligence; (c) to normal maintenance services and the parts used in connection with such service; (d) to 
units which are not installed in accordance good trade practices; or (e) to unit used for purposes other than for what it 
was designed and manufactured.  

 
RETURN OR REPLACED COMPONENTS: any item to be replaced under this Warranty must be returned to 
TCW Technologies in Emmaus, PA, or such place as TCW may designate, freight prepaid. 
 
PRODUCT IMPROVEMENTS: TCW reserves the right to change or improve its products or any portions 
thereof without being obligated to provide such a change or improvement for units sold and /or shipped prior 
to such change or improvement. 
 
WARRANTY EXCLUSIONS: as to any specific TCW product, after the expiration of the time period of the 
warranty applicable thereto as set forth above. THERE WILL BE NO WARRANTIES, INCLUDING ANY 
IMPLIED WARRANTIES OR MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. 
 
Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not 
apply to you. No warranties or representations at any time made by any representative of TCW shall vary or 
expand the provisions hereof. 
 
LIABILITY LIMITATION: IN NO EVENT SHALL TCW OR ITS AFFILIATES BE LIABLE OR RESPONSIBLE 
FOR CONSEQUENTIAL, INCIDENTAL OR SPECIAL DAMAGES RESULTING FROM OR RELATED IN ANY 
MANNER TO ANY TCW PRODUCT OR PARTS THEREOF. THE SUITABILITY OF USE OF THE TCW 
TECHNOLGIES, LLC. PRODUCT IS TO BE DETERMINED BY THE AIRCRAFT BUILDER. 
 
Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above 
limitation or exclusion may not apply to you. 
 
This Warranty gives you specific legal rights and you may also have other rights which vary from state to 
state. In the absence of other suitable proof of this installation date, the effective date of this Warranty will be 
based upon the date of manufacture plus one year. Direct All Notices To: Warranty and Product Service 
Department, TCW Technologies, 2955 Main Road East, Emmaus, PA 18049 

 

 

 

 

Содержание IBBS-12v-2ah

Страница 1: ...output power during normal and emergency operations The IBBS system also provides an output signal to communicate the operating state of the back up bus as well as the state of the battery The IBBS sy...

Страница 2: ...lect an installation location that will comply with these requirements 4 Connect the aircraft wiring according to one of the wiring diagrams shown The IBBS must be powered through a properly sized cir...

Страница 3: ...tem connections directly to aircraft battery must be utilized as shown 8 When using the IBBS product to provide back up power to an electronic ignition system CDI pullable circuit breakers must be use...

Страница 4: ...on the input of the IBBS the info line may be read to determine the internal battery voltage A nominal battery with a full charge will read between 12 and 15 volts When the IBBS is on line providing b...

Страница 5: ...harged battery the following average performance can be expected in terms of operating duration The operating duration is for output voltage down to 9 5 volts Nominal Current Draw Duration total conne...

Страница 6: ...procedures Start up Procedure 1 Prior to turning on the Aircraft Master Switch turn ON the Back up Power master switch 2 Turn on any equipment that derives back up power from the IBBS product 3 Ensure...

Страница 7: ...he Back up Power Master Switch 3 Turn on all equipment connected to and supplied with back up power from the IBBS product 4 Measure and record at least the following information The time until the fir...

Страница 8: ...operation based on the use of only the electronic ignition module provided with back up battery power 3 PULL the 5 amp breaker feeding the Back up Master Switch confirm engine continues to run 4 PULL...

Страница 9: ...ullable breakers to the normal ON position and ensure aircraft engine is properly returned to the off position by following normal run and shut down procedures 10 After completing these tests recharge...

Страница 10: ...l high performance fast charger Surge Protection 16 volt active clamp 1500w 10 1000uS waveform Wiring CPC connector with Mil spec machined contacts Field replaceable inline fuse AGC 7 5 Enclosure Cast...

Страница 11: ...rness PIN Description Wire Color optional harness 1 Main Aircraft Bus charge power Red 2 Aux Battery trickle charge Always ON Purple yellow 3 Aircraft ground Black 4 Back up power master switch White...

Страница 12: ...g 20 awg www tcwtech com Emmaus PA USA MODEL IBBS 12V 2AH Input 10 15 volts DC Output 12 volts 3 amps Capacity 2 amp hours INTEGRATED Back up Battery SYSTEM Pin 1 Main Aircraft Bus Pin 2 Aux Battery t...

Страница 13: ...hout back up power inputs Equipment without Back up Power Input 2 amps 10 amp Main Aircraft Bus Aux Battery trickle charge Back up Power Master cpc connector INFO Low active signal High battery voltag...

Страница 14: ...x Battery trickle charge Back up Power Master cpc connector INFO Low active signal High battery voltage Back up power input 20 awg 22 awg 22 awg 20 awg 20 awg 22 awg 20 awg www tcwtech com Emmaus PA U...

Страница 15: ...REV 2 3 2012 TCW Technologies LLC 15 Main Aircraft Bus 20 awg Shielded...

Страница 16: ...REV 2 3 2012 TCW Technologies LLC 16...

Страница 17: ...Emmaus PA or such place as TCW may designate freight prepaid PRODUCT IMPROVEMENTS TCW reserves the right to change or improve its products or any portions thereof without being obligated to provide su...