background image

REV 2.3 

 

     © 2012 TCW Technologies, LLC. 

10

 
SPECIFICATIONS: 
 
 
Input Voltage:   

10-15 volts DC 

 
Input Current 

 

4.8 amps max continuous 

 
Output Voltage:  

10-12 volts DC during back-up operation 

 
Output Current:  

3 amps continuous 

 
Battery: 

 

 

Internal sealed Ni-MH  

 
Charger: 

 

 

Integral high performance fast charger 

 
Surge Protection:   

16 volt active clamp, 1500w 10/1000uS waveform 

 
Wiring: 

 

 

CPC connector with Mil-spec machined contacts 

 

 

 

 

Field replaceable inline fuse:   AGC-7.5  

 
Enclosure:   

 

Cast aluminum 

 

 

 

 

5.8” x 3.7” x 1.3” (including mounting flange) 

 

 

 

 

 

Weight: 

 

 

1.5 lbs 

 
Temperature range: 

Operating  -10 C° to 60 C° 

 

 

 

 

Charging 

0 C° to 40 C° 

 

 

 

 

Connectors:     

AMP type CPC # 206486-2 on product wiring harness. 
AMP type CPC # 206485-1 is utilized on the aircraft wiring 

 

harness. 

 

 

 

 

 

 
 
 
 
 
 
 
 
 

Содержание IBBS-12v-2ah

Страница 1: ...output power during normal and emergency operations The IBBS system also provides an output signal to communicate the operating state of the back up bus as well as the state of the battery The IBBS sy...

Страница 2: ...lect an installation location that will comply with these requirements 4 Connect the aircraft wiring according to one of the wiring diagrams shown The IBBS must be powered through a properly sized cir...

Страница 3: ...tem connections directly to aircraft battery must be utilized as shown 8 When using the IBBS product to provide back up power to an electronic ignition system CDI pullable circuit breakers must be use...

Страница 4: ...on the input of the IBBS the info line may be read to determine the internal battery voltage A nominal battery with a full charge will read between 12 and 15 volts When the IBBS is on line providing b...

Страница 5: ...harged battery the following average performance can be expected in terms of operating duration The operating duration is for output voltage down to 9 5 volts Nominal Current Draw Duration total conne...

Страница 6: ...procedures Start up Procedure 1 Prior to turning on the Aircraft Master Switch turn ON the Back up Power master switch 2 Turn on any equipment that derives back up power from the IBBS product 3 Ensure...

Страница 7: ...he Back up Power Master Switch 3 Turn on all equipment connected to and supplied with back up power from the IBBS product 4 Measure and record at least the following information The time until the fir...

Страница 8: ...operation based on the use of only the electronic ignition module provided with back up battery power 3 PULL the 5 amp breaker feeding the Back up Master Switch confirm engine continues to run 4 PULL...

Страница 9: ...ullable breakers to the normal ON position and ensure aircraft engine is properly returned to the off position by following normal run and shut down procedures 10 After completing these tests recharge...

Страница 10: ...l high performance fast charger Surge Protection 16 volt active clamp 1500w 10 1000uS waveform Wiring CPC connector with Mil spec machined contacts Field replaceable inline fuse AGC 7 5 Enclosure Cast...

Страница 11: ...rness PIN Description Wire Color optional harness 1 Main Aircraft Bus charge power Red 2 Aux Battery trickle charge Always ON Purple yellow 3 Aircraft ground Black 4 Back up power master switch White...

Страница 12: ...g 20 awg www tcwtech com Emmaus PA USA MODEL IBBS 12V 2AH Input 10 15 volts DC Output 12 volts 3 amps Capacity 2 amp hours INTEGRATED Back up Battery SYSTEM Pin 1 Main Aircraft Bus Pin 2 Aux Battery t...

Страница 13: ...hout back up power inputs Equipment without Back up Power Input 2 amps 10 amp Main Aircraft Bus Aux Battery trickle charge Back up Power Master cpc connector INFO Low active signal High battery voltag...

Страница 14: ...x Battery trickle charge Back up Power Master cpc connector INFO Low active signal High battery voltage Back up power input 20 awg 22 awg 22 awg 20 awg 20 awg 22 awg 20 awg www tcwtech com Emmaus PA U...

Страница 15: ...REV 2 3 2012 TCW Technologies LLC 15 Main Aircraft Bus 20 awg Shielded...

Страница 16: ...REV 2 3 2012 TCW Technologies LLC 16...

Страница 17: ...Emmaus PA or such place as TCW may designate freight prepaid PRODUCT IMPROVEMENTS TCW reserves the right to change or improve its products or any portions thereof without being obligated to provide su...

Отзывы: