19
Weights & Measures
Mass Density
To provide a calculated Mass value, determine the value to input Mass
Density and press ENTER.
Mass = Density X Volume
Pump Control & Timing Enable/Disable Pump Control and select ENTER.
- Pump is an Optional Output Control
- Enabled means that the pump control will energize whatever element of
the truck you’ve connected to.
- Disabled means that the pump control is not active and will not energize.
Pump Starter to enter the Start Duration time in seconds, then press
ENTER.
Pump Starter Advance to enter Starter Advance time in Seconds, then
press ENTER.
Pump Stabilization is used to enter how long you wish the Pump Starter
stays powered. Enter value in Seconds and press ENTER.
Valve Type
Select whether you are using a Single or Dual Stage Valve and press
ENTER
- A Single Stage valve will energize valve with Solenoid 1.
- A Dual Stage valve will energize valve with Solenoids 1 and 2.
DUAL
-1101
Both S1 and S2 energize at the beginning of delivery and near the end of the delivery
S1 shuts off and S2 is still operating.
-1001
At the beginning of the delivery the S1 valve opens energizes while the S2 remains
closed until near the end of the delivery, then S1 closes and S2 opens.
Unit of Measure
Gram/cm3
Gram/Cubic Centimeter
Gram/m3
Gram/Cubic Meter
Kilogram/m3
Kilogram/Cubic Meter
Milligram/m3
Milligram/Cubic Meter
Pound/ft3
Pound/Cubic Foot
Pound/in3
Pound/Cubic Inch
Ton/yard3
Ton/Cubic Yard