Indication and operating elements
Term
Function
Reset
push button
for reset, restart the software
to reload the factory settings
button
Reload to
factory setting WE
to reload the factory setting
Anzeige
Status TCS:BUS
(rote LED)
OFF
: stand-by
ON
: during a voice connection between TCS:BUS and PBX / PSTN
both LEDs ON
: when reloading the factory setting
blinks slowly
: busy (voice connection or alarming, announcement)
blinks fast
: a-wire is not connected or supplied
flashes OFF
: device is activated for programming with configuration software
configo™
flashes ON
: door call, internal call or sensor signal received
flashes ON, once, long break
: a-, P-wire are interchanged or short-circuited
flashes oN, twice, long break
: error duplication of the block number and
different device versions
flashes ON, three times, long break
: error duplication of the block number
in case of identic devices
Status indication PBX
/ PSTN connection
(yellow LED)
OFF
: error P-wire is not connected or not supplied
ON, briefly
: as long as a call signal comes in at the TK-Interface
ON
: after a door call, during connection establishment and voice connection
both LEDs ON
: when reloading to factory settings
blinks slowly
: programming mode active
blinks fast
: once, connection to the PBX / PSTN cannot be realised, busy
flashes OFF
: after a door call with deviated connection etsablishment, until
the end of the delay time
flashes ON
: connection to the sensor without speaking
flashes ON, four times, long break
: variant dial number from 1 to 99999
Intended use
The FBO1200 is an interface for the connection from the TCS:BUS to a telephone net in
ordert o establish a voice connection between a TCS:BUS client (front-door or indoor
stations) and client with telephone net.
The connection is realised via an analogue port.
Only a FBO1200 can be connected to a TCS:BUS.
Devices type FBO1200 cannot be combined with devices type FBO1100.
!
FBO1100 and FBO1200 must
not
be connected simultaneously to a TCS:BUS!
Note:
If there is more than FBO1200 connected to a TCS:BUS, this error is signalled by the red LED (flashes
three times, long break, see also Error detection and indication, page 10 ).