Reload to factory settings  

All programmed parameter are deleted within one process.  

This is necessary, e.g. in case the identification number for the programming mode is lost. 
This number can be reset only to 

0000

 by reloading the factory setting.  

 

      

 

 
 

  Press the button

 Reload factory settings

 and keep it pressed. 

  At the same time, shortly press the 

Reset 

button. 

  Release the button

 Reload factory settings.

 The factory settings are reloaded. The pro-

cess takes around 2 s. During this time the actuator output is active. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Содержание FBO1200-0400

Страница 1: ...e Germany 49 0 41 94 9 88 11 88 Subject to technical changes FAX 49 0 41 94 9 88 129 Mail info tcsag de PI_FBO1200 uk 1A Product information Interface for TK systems FBO1200 0400 Attention Please obse...

Страница 2: ...iagram minimum installation 7 Commissioning 8 Functional principle 8 Legend 8 Acknowledgement and signal tones after a call 8 Keystroke 8 Used abbreviations 8 Commissioning steps 9 Error detection and...

Страница 3: ...alternating voltage the safety regu lations according to DIN VDE 0100 must be observed When installing TCS BUS systems the general safety regulations for telecommunication systems according to VDE 08...

Страница 4: ...technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FBO1200 uk 1A Device overview connection TCS BUS connection sensor connection actuator connection PBX PSTN Reset push button push but...

Страница 5: ...tus indication PBX PSTN connection yellow LED OFF error P wire is not connected or not supplied ON briefly as long as a call signal comes in at the TK Interface ON after a door call during connection...

Страница 6: ...g register with a standard cell phone telephone day night mode call diversion from the indoor station to the TK Interface actuatot potential free relay contact two way contact 24 V DC 1 A switch time...

Страница 7: ...rControlSysteme AG TCS Hotline Germany 49 0 41 94 9 88 11 88 Subject to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FBO1200 uk 1A Eiring diagram minimum installation PBX PSTN an...

Страница 8: ...e PI_FBO1200 uk 1A Commissioning Functional principle Legend Acknowledgement and signal tones after a call aQ programming mode ON entry is stored aQ call at the TK Interface aQ entry invalid aH end of...

Страница 9: ...with a long break blink mode also see Indication and operating elements page 5 First check the connection of the FBO1200 to the telephone system with a call to the telephone number which is assigned t...

Страница 10: ...sounds for three times audible at the telephone then the connection is disconnedted The red LED at the TK Interface blinks or flashes permantly see table below The optical error indication at the TK...

Страница 11: ...x x 26 set the delay of the dialing start x x 27 not available acknowledgement invalid entry 28 not available acknowledgement invalid entry 29 not available acknowledgement invalid entry 30 duration o...

Страница 12: ...Service function listen in 0 can be activated with the button Reload factory settings 1 activate always automatically 0 0 PSTN 1 PBX 2 Hotline 2 0 X Not available acknowledgement invalid entry 0 PBX...

Страница 13: ...PIN 2 HW Reset 3 9 X Activate the function of an input PIN 0 0 short 1 long 4 0 X Set the timeout after the dial short 10 s long 45 s 1 0 16bit short 1 32 bit long 4 1 X Set the door release command...

Страница 14: ...Germany 49 0 41 94 9 88 11 88 Subject to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FBO1200 uk 1A Programming modeON OFF via TCSK 01 aQ program ming mode ON TK Interface accept...

Страница 15: ...9 0 41 94 9 88 11 88 Subject to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FBO1200 uk 1A Settings Communication time Number of ring tones signals aQ entry is stored TK Interfac...

Страница 16: ...88 Subject to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FBO1200 uk 1A Actuator output switch time Call time Change the PIN aQ entry is stored aQ entry is stored TK Interface...

Страница 17: ...in one process This is necessary e g in case the identification number for the programming mode is lost This number can be reset only to 0000 by reloading the factory setting Press the button Reload f...

Страница 18: ...handset button of the mobile telephone or lifting the handset Can be changed with the configuration software configo as of version 1 8 x Technical data supply voltage 26 V DC power supply and control...

Страница 19: ...has to be disposed separateley from domestic waste The materials used are recyclable Please do help protecting our environment and dispose the device via a collection point for electronic scrap Dispo...

Страница 20: ...to technical changes FAX 49 0 41 94 9 88 129 Mail hotline tcsag de PI_FBO1200 uk 1A Service Please send your questions and inquiries to hotline tcsag de Headquarters TCS T rControlSysteme AG Geschwis...

Отзывы: