Safety notices
!
Assembly, installation, and commissioning must only be carried out by a qualified electrician!
For work on systems with 230 V AC mains voltage the safety requirements of DIN VDE 0100
must be observed.
When installing TCS:BUS systems the general safety rules for telecommunication systems in
accordance with VDE 0800 must be observed:
separate cabling for high and low voltage lines,
minimum distance of 10 cm for joint cabling arrangements,
use of separators between high and low voltage lines in joint cable ducts,
use of standard telecommunication cables, e. g. J-Y (St) Y with 0.8 mm diameter,
existing cables (modernisation) with different cross sections may be used whilst taking ac-
count of the loop resistance.
!
Suitable lightning protection must ensure that a voltage of 32 V DC will not be exceeded at
the TCS:BUS wires a and b.