background image

14 

Programming the bell buttons  

Basic principle 

All devices at the TCS:BUS have an unique serial number.  
The serial number of the indoor station is allocated to the bell button of the front door station. The alloca-
tion is stored in the EEPROM of the front door station.  
 
Requirements for the programming: 

 Ensure that the access to the indoor station in the flat is granted. 

 Check if the indoor station is connected to the TCS:BUS. 

 Switch on the mains voltage. The operating LED at the power supply and control unit is on. 

 Check if a programming lock is set. 

 

Manual TCSK

 

 

If the programming lock is activated, you cannot program any bell button. 
To deactivate the programming lock you need a Service Device TCSK or the configuration 
software configo™. 

 
 

Power supply and control unit: switch on the programming mode of the system 

 

 

  

Shortly press 

a)

 the  

RUN/PROG button.  

The LED blinks. 

The programming mode of the system is 
switched ON. 

Deleting bell buttons 

b)

 

 

 

 

 

 

Press the button which should be deleted for 6 seconds  
until an acknowledgement tone sounds. 

c)

 

Release the bell button.  
Repeat step 2 to delete  
further bell buttons. 

Programming via voice communication  

 

 

 

 

 

Establish a voice 
communication to the 
front door station. 

d)

 

Press the bell 
button which 
should be pro-
grammed. 

A ring tone sounds at the front door and indoor 
station. 

c)

 

Terminate the voice 
communication. 

 
 

Содержание ASX1300 -0010 Series

Страница 1: ...Product information Audio front door station series ASX1300x 0010 for surface mount...

Страница 2: ...2...

Страница 3: ...ns 5 requirements to protect against lightning 5 Product description 6 Intended use 6 Short description 6 Device overview 7 Technical data 7 Mounting and installation 8 Installation 8 Connecting the l...

Страница 4: ...em manual available in the download area at www tcsag de Used symbols and warning notices Symbol signal word Explanation DANGER The signal word describes an endangering with a high level of risk Failu...

Страница 5: ...sys tems according to VDE 0800 must be observed Inter alia separated cable routing of high and low voltage lines minimum distance of 10 cm in case of a common cable routing use of separators between h...

Страница 6: ...bell push button 2 indoor stations can be allocated durable and energy saving nameplate illumination shatter proof nameplate glass acknowledgement tone when pressing the bell button conversation time...

Страница 7: ...rophone 12 bell button with labelling Technical data supply voltage 24 V 8 power supply and control unit input current in resting position 3 wire operation I a 0 4 mA I P 9 13 mA maximum input current...

Страница 8: ...it to ensure a proper func tion of the microphone Fig 1 Mounting height Opening the device The upper part of the housing is screwed together with the rear panel via a hexagon socket screw Fig 2 Loosen...

Страница 9: ...l do not get clamped Fig 3 Assembling the rear panel Connecting the lines Strip the lines Connect the lines a b and P according to the labelling 1 Fig 4 Observe the example circuit on page 12 2 wire t...

Страница 10: ...iate socket Fig 6 Put on the upper part of the housing 2 onto the rear panel Fig 7 Turn down the upper part of the housing onto the rear panel 3 Fix the upper part of the housing to the rear panel wit...

Страница 11: ...es made of paper We recommend to print out the nameplates on a durable special foil made of plastics You can order replacement foils directly under E Mail info tcsag de or use our labelling service ww...

Страница 12: ...12 Example circuit Fig 10 Circuit diagram For further information see TCS system manual The TCS system manual can be downloaded at www tcsag de...

Страница 13: ...ex works A change is not always required Adjust the loudspeaker volume Turn the control 1 right to increase the volume of the loud speaker Fig 11 Turn the control 1 left to reduce the volume of the l...

Страница 14: ...ramming lock is activated you cannot program any bell button To deactivate the programming lock you need a Service Device TCSK or the configuration software configo 1 Power supply and control unit swi...

Страница 15: ...on c IftheresoundsaProgsperrtone longhightonefollowedbylonglowtone instead thefrontdoorstationisequippedwithaprogramming lock YoucandeactivatetheprogramminglockonlywiththeservicedeviceTCSKortheconfigu...

Страница 16: ...Our standard terms and conditions of sale you ll find under www tcsag de Spare parts accessory Short text Article number laser film foil matt format DIN A4 nameplates 0001060 special wrench 0012493 w...

Отзывы: