background image

15

periods of guarantee.

      6.3.4. Any repairs or substitutions covered under this guarantee must be parts that are functionally 
equivalent. The defective parts or parts removed or replaced shall become the property of TCP Smart.

6.4. The technical service of TCP Smart will advise you if you need to buy any parts not covered under the 
guarantee or out of guarantee.

6.5. This guarantee does not affect the buyer’s legal rights stipulated in the current national legislation, nor affects 
those rights against the distributor or installer that could come forth in compliance with the purchase contract. 

6.6. In the absence of a national legal legislation applicable, this guarantee shall prevail and may be construed 
as the buyer’s only protection. TCP Smart, its offices, distributors and installers may not be held responsible 
for any accidental damage that emerges due to infringement of any rules implicitly related to this product. 

7. Erp Directive Information requirements. Regulation (EU) 2015/1188 

Item

Symbol

Unit

CRI1100RADC

CRI1300RADC

CRI1500RADC

HEAT OUTPUT

Nominal heat output

Pnom

kW

1.1

1.3

1.5

Minimum heat output  (indicative)

Pmin

kW

N.A.*

N.A.*

N.A.*

Maximum continuous heat output

Pmax,c

kW

1.1

1.3

1.5

AUXILIARY ELECTRICITY CONSUMPTION

At nominal heat output 

elMAX

kW

1.1

1.3

1.5

At minimum heat output

elMIN

kW

1.1

1.3

1.5

In standby mode

elSB

kW

0,0008

0,0008

0,0008

TYPE OF HEAT OUTPUT/ROOM TEMPERATURE CONTROL (SELECT ONE)

Single stage heat output and no room temperature control

Two or more manual stages, no room temperature control

With mechanic thermostat room temperature control

With electronic room temperature control

Electronic room temperature control plus day timer

Electronic room temperature control plus week timer

OTHER CONTROL OPTIONS (MULTIPLE SELECTIONS POSSIBLE)

Room temperature control, with presence detection

Room temperature control, with open window detection

With distance control option

With adaptive start control

With working time limitation

With black bulb sensor

SEASONAL SPACE HEATING ENERGY EFFICIENCY

ηs

39,0%

39,0%

39,0%

 

CONTACT DETAILS

Technical Consumer Products Ltd - Unit 1, Exchange Court, Cottingham Road, Corby, Northamptonshire NN17 1TY | [email protected]

 

*Not applicable

Содержание CRI1100RADC

Страница 1: ...TCP Smart Wi Fi conservatory radiator Digital electric radiator with thermal fluid and Wi Fi inside module INSTRUCTION INSTALLATION GUIDE EN...

Страница 2: ...enance should not be carried out by children without supervision Children must be supervised at all times to ensure that they do not interfere with the product This product is filled with a precise am...

Страница 3: ...4 TCP Smart radiator Information Instructions 6 4 1 Touchpad 6 4 2 Screen 7 4 3 Turn On and Off 7 4 4 Submenu configuration 8 4 5 Locking touchpad 9 4 6 Selecting MANUAL AUTOMATIC or PILOTE WIRE 9 4 7...

Страница 4: ...0 5 23 Finish White RAL 9010 ELECTRICAL CHARACTERISTICS Nominal Power W 1 100 1 300 1 500 Voltage V 230 V 230 V 230 V Current A 4 8 5 7 6 6 INSTALLATION PROTECTION Template Installation Kit Safety the...

Страница 5: ...om the floor and 30cm at the most As for the sides and above a minimum distance of between 10 12cm must be left from any wall or brickwork in order for it to function correctly Figure 2 3 2 Fixing the...

Страница 6: ...505 mm 225 mm 400 mm 880 mm 444 mm 505 mm 225 mm 1500RADC 400 mm 880 mm 444 mm 505 mm 225 mm 4 TCP Smart radiator Information Instructions 4 1 Touchpad Settings Back ON OFF Confirm Decrease temperatu...

Страница 7: ...icator 13 Open Windows indicator 14 Energy consumption indicator 4 3 Turn On and Off To turn the product on press the button once To turn off press the button again When you turn the product on for th...

Страница 8: ...buttons to select the correct day and press the button to confirm 4 4 2 Adjust brightness This function allows you to adjust the brightness when the product is on or in standby To adjust the brightnes...

Страница 9: ...u to select between MANUAL or AUTOMATIC mode PRE PROGRAMS allows you to select one of the 4 default programming schedules USER PROGRAM allows you to edit or create programming PILOT WIRE allow externa...

Страница 10: ...already established in the product will be activated You can choose between the four pre installed schedules in your TCP Smart product PRE PROGRAM 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19...

Страница 11: ...by a box Use the buttons to move between the days Press after day 7 to go to the next step STEP 3 1 Select the programming mode for the hours Use the buttons to move between the hours Select a program...

Страница 12: ...OPEN WINDOWS mode is activated for two hours When the OPEN WINDOWS mode is active the radiator will be in ANTI FROST mode at 7 C 4 7 2 BALANCE function The BALANCE submenu causes the product to work i...

Страница 13: ...product on the aluminium Clean it with a damp cloth and a pH neutral soap and the control panel with a dry cloth European Directive 2012 19 UE Under the European Directive 2012 19 UE on waste electric...

Страница 14: ...nditions as follows 6 3 1 The guarantee is only applicable if the original guarantee is issued by the seller and when the said guarantee is filled in correctly including product reference series numbe...

Страница 15: ...CRI1300RADC CRI1500RADC HEAT OUTPUT Nominal heat output Pnom kW 1 1 1 3 1 5 Minimum heat output indicative Pmin kW N A N A N A Maximum continuous heat output Pmax c kW 1 1 1 3 1 5 AUXILIARY ELECTRICI...

Страница 16: ...es and other printed materials TCP Smart reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subse...

Отзывы: