    4.7.  Advanced features of the TCP Smart radiator

The TCP Smart radiator includes four advanced functions. To activate or deactivate one of the 
functions below, press the   button to access the settings menu. Use the 

 buttons to scroll 

through the menu until you find the 

POWER

 submenu. Press the    button to access the submenu:

1. Open Windows

2. Balance

3. Adaptive mode

      

By accessing each of them, you can activate or deactivate its operation. Once selected, press the 

 button and use the 

 buttons to activate or deactivate the function. Press the   button once 

more to confirm the option.

        4.7.1. OPEN WINDOWS function

The TCP Smart radiator has the OPEN WINDOWS  

  function activated as a default. This function 

is activated when the sensor detects that there has been a temperature decrease of 4°C in a period 
of 30 minutes. The OPEN WINDOWS mode is activated for two hours. When the OPEN WINDOWS 
mode is active, the radiator will be in ANTI-FROST mode at 7ºC.

        4.7.2. BALANCE function

The 

BALANCE

 submenu causes the product to work in Manual mode with a constant temperature of 

19ºC. Once selected, the product returns to the main screen, with the temperature set at 19ºC and 
the 

MANUAL

 function icon activated.

        4.7.3. ADAPTATIVE mode

Adaptive mode allows the product to learn how long it will take to heat the room to your desired 
temperature. It predicts the ideal time to activate the heating element to reach the temperature set, 
at exactly the right time you programmed, saving you time, energy and money.

    4.8.  Wi-Fi pairing

The Wi-Fi submenu allows you to enable / disable the connection and perform pairing with a device.
Selecting the option “pair the product” will create its own network to which you can connect your 
device. The following screen will show the data of the created network (NET) and the password (PIN) 
for the product you want to pair.

Содержание CRI1100RADC

Страница 1: ...TCP Smart Wi Fi conservatory radiator Digital electric radiator with thermal fluid and Wi Fi inside module INSTRUCTION INSTALLATION GUIDE EN...

Страница 2: ...enance should not be carried out by children without supervision Children must be supervised at all times to ensure that they do not interfere with the product This product is filled with a precise am...

Страница 3: ...4 TCP Smart radiator Information Instructions 6 4 1 Touchpad 6 4 2 Screen 7 4 3 Turn On and Off 7 4 4 Submenu configuration 8 4 5 Locking touchpad 9 4 6 Selecting MANUAL AUTOMATIC or PILOTE WIRE 9 4 7...

Страница 4: ...0 5 23 Finish White RAL 9010 ELECTRICAL CHARACTERISTICS Nominal Power W 1 100 1 300 1 500 Voltage V 230 V 230 V 230 V Current A 4 8 5 7 6 6 INSTALLATION PROTECTION Template Installation Kit Safety the...

Страница 5: ...om the floor and 30cm at the most As for the sides and above a minimum distance of between 10 12cm must be left from any wall or brickwork in order for it to function correctly Figure 2 3 2 Fixing the...

Страница 6: ...505 mm 225 mm 400 mm 880 mm 444 mm 505 mm 225 mm 1500RADC 400 mm 880 mm 444 mm 505 mm 225 mm 4 TCP Smart radiator Information Instructions 4 1 Touchpad Settings Back ON OFF Confirm Decrease temperatu...

Страница 7: ...icator 13 Open Windows indicator 14 Energy consumption indicator 4 3 Turn On and Off To turn the product on press the button once To turn off press the button again When you turn the product on for th...

Страница 8: ...buttons to select the correct day and press the button to confirm 4 4 2 Adjust brightness This function allows you to adjust the brightness when the product is on or in standby To adjust the brightnes...

Страница 9: ...u to select between MANUAL or AUTOMATIC mode PRE PROGRAMS allows you to select one of the 4 default programming schedules USER PROGRAM allows you to edit or create programming PILOT WIRE allow externa...

Страница 10: ...already established in the product will be activated You can choose between the four pre installed schedules in your TCP Smart product PRE PROGRAM 1 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19...

Страница 11: ...by a box Use the buttons to move between the days Press after day 7 to go to the next step STEP 3 1 Select the programming mode for the hours Use the buttons to move between the hours Select a program...

Страница 12: ...OPEN WINDOWS mode is activated for two hours When the OPEN WINDOWS mode is active the radiator will be in ANTI FROST mode at 7 C 4 7 2 BALANCE function The BALANCE submenu causes the product to work i...

Страница 13: ...product on the aluminium Clean it with a damp cloth and a pH neutral soap and the control panel with a dry cloth European Directive 2012 19 UE Under the European Directive 2012 19 UE on waste electric...

Страница 14: ...nditions as follows 6 3 1 The guarantee is only applicable if the original guarantee is issued by the seller and when the said guarantee is filled in correctly including product reference series numbe...

Страница 15: ...CRI1300RADC CRI1500RADC HEAT OUTPUT Nominal heat output Pnom kW 1 1 1 3 1 5 Minimum heat output indicative Pmin kW N A N A N A Maximum continuous heat output Pmax c kW 1 1 1 3 1 5 AUXILIARY ELECTRICI...

Страница 16: ...es and other printed materials TCP Smart reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subse...

Отзывы: