TCO ICon Pro Скачать руководство пользователя страница 13

 
 

 

13 

3

 

Safety 

Safety comes first, therefore please take time to read and understand these safety instructions. 

Improper use can cause harm or void the manufacturer’s warranty. 

 

 

3.1

 

General safety instructions 

The ICon Pro is an electrical appliance. Please read the safety instructions before use and take the 
necessary precautions to reduce the risk of fire, electric shock or injury.  
 

 

Never perform repairs yourself, always use the professional service of your ICon Pro supplier.  

 

Do not use ICon Pro when in alarm/error mode. Always consult your supplier before using it 
again, unless the problem is solved following our Trouble shooting guide on page 30.  

 

Always use the replacement filters recommended by your ICon Pro supplier.  

 

Always switch off and unplug the unit before replacing the pre-filter and the main HEPA filter.  

 

Always follow the instructions in this user manual to ensure long and trouble-free use. 

 

3.2

 

Machine orientation 

Always place the ICon Pro in an upright position. 
Once correctly placed on location, always lock 
the brakes on the front caster wheels (Figure 5, 
pos. 1) when the ICon Pro

 

is in operation.  

Push the red brake lever down to lock the 
brake, pull it up to unlock the brake. 

 
 
 
 
 
 
 
 

 

 

Figure 5 

 

 

4

 

Transport and storage 

 

CAUTION 

Always keep the body of the ICon Pro in an upright position when moving it. 

 
 
 
 
 
 

 

Содержание ICon Pro

Страница 1: ...ICon Pro user manual TCO Sp z o o Tyniecka 126C 30 376 Krakow Poland T 48 12 268 3218 E hello thecleanair eu I www iconairhealer eu...

Страница 2: ...nguage TCO Sp z o o Tyniecka 126C 30 376 Krakow Poland T 48 12 268 3218 E hello thecleanair eu I www iconairhealer eu Model ICon Pro Date 25 03 2020 Product code ICon 2020 01 Version 1 3 Distributor a...

Страница 3: ...refers to the manufacturer this means TCO Sp z o o in Krak w Poland When this manual mentions the partner your local TCO resell and support service partner is referred to Purpose of the user manual Th...

Страница 4: ...followed can lead to injuries of the operator or bystanders light and or moderate damage to the product or the environment CAUTION Indicates a hazardous situation which if the safety instructions are...

Страница 5: ...Working principle 12 3 Safety 13 3 1 General safety instructions 13 3 2 Machine orientation 13 4 Transport and storage 13 5 Assembly and installation 14 5 1 Unboxing 14 5 1 1 Unboxing your ICon Pro 15...

Страница 6: ...eaning 28 7 4 Ordering replacement filters 28 7 5 Service interval UV lamps 29 8 Trouble shooting 30 9 Decommissioning and disposal 31 10 Attachments 32 10 1 Technical specifications 32 General specif...

Страница 7: ...se of chemicals including cleaning chemicals using proper filters in vacuum cleaners and reducing cross contamination between rooms and buildings improve ventilation often a difficult and expensive so...

Страница 8: ...inlet and filters 1 3 Lifespan CAUTION ICon Pro is designed to work almost maintenance free for a long time You should not need to contact an authorized TCO partner before 4 years of running ICon Pro...

Страница 9: ...9 1 5 Specifications Figure 1 Product body unit 1273 684 334 mm Weight 72 kg Control panel on front of unit yes Transport wheels yes...

Страница 10: ...nty period is 24 months Warranty conditions you will find on www iconairhealer eu resources 1 7 Identification Each ICon Pro has a unique identification number that can be found on the back side of th...

Страница 11: ...ilter compartment Attached to the inside of the compartment panel you will find a 2 5 Allen wrench to be used for opening the panel of the pre filter compartment 6 Neutralization chamber panel only to...

Страница 12: ...r filtration of the smallest particles even smaller than 0 3 The clean air leaves the unit through the air outlet Figure 4 pos 6 on the front of the ICon Pro unit 1 HEPA filter 2 Fan 3 Neutralizing ch...

Страница 13: ...e using it again unless the problem is solved following our Trouble shooting guide on page 30 Always use the replacement filters recommended by your ICon Pro supplier Always switch off and unplug the...

Страница 14: ...newly delivered ICon Pro consists of these items Figure 6 1 1x ICon Pro unit 2 1x power cable 3 1x this user manual We care about our environment Therefore we use as little non recyclable packaging m...

Страница 15: ...r boards Figure 7 pos 3 and 7 5 Remove the double honeycomb paper board from underneath your ICon Pro Figure 7 pos 4 6 Unlock the caster wheels Figure 7 pos 5 and pull your ICon Pro out of the box 7 R...

Страница 16: ...on a solid and level surface on a location where the ICon Pro and its power cable do not form an obstacle 6 2 Main power on off 1 Insert the power cable into the power cable socket of the ICon Pro an...

Страница 17: ...teria in the air are relatively high The boost function doubles the power of the neutralization chamber 1 Press the boost switch to turn on the boost function Figure 9 pos 1 The system will sound a si...

Страница 18: ...gure 8 pos 2 The red LED indicator on the main power switch is lit The left green LED indicator Figure 10 pos 1 on the control panel is lit 12 Press the operating knob Figure 10 pos 5 to activate the...

Страница 19: ...hould be set Always do care about the room users comfort A higher fan speed results in a higher noise level Whenever it is possible run you ICon Pro on a Low or Medium mode during the working hours Wi...

Страница 20: ...noon to 24 midnight 1 Select and confirm the day of the week you want to program 2 Select and confirm 00 11 OOOOOOOOOOOO 3 Select and confirm the first hour O 4 Select and confirm the Fan level F Max...

Страница 21: ...n the outgoing air g m3 is equal to parts per million Micrograms per m3 is what is called ppm What is considered a safe level of dust in the air varies from country to country A level below 15ppm of P...

Страница 22: ...best results in neutralization with UV lamps lifespan of 4 years when operating 24 7 So you don t have to worry about it for a long time The life time of the lamps will vary when the boost function i...

Страница 23: ...ur computer screen Or you may set up the automatic working mode of your ICon Pro Navigation throughout the web menu is designed for use by advanced users only Back Figure 15 6 4 6 1 Settings The setti...

Страница 24: ...hone support will do Fan locked NO main unit operations are fine no problem Error the main fan is locked by the system for example when filters has to be changed VOC sensor OK sensor fully operational...

Страница 25: ...tment panel and the main ICon Pro unit DO NOT disconnect it from the main ICon Pro unit 3 Pull the filter lock Figure 18 pos 1 forward and push it down 4 Take the pre filter by the handle on the front...

Страница 26: ...screws 4x 10 NOTE Make sure that the ground wire Figure 17 pos 2 is always connected to the compartment panel If needed attach again ATTENTION The pre filter collects heavy dirt and keeps it away fro...

Страница 27: ...n the compartment panel NOTE There is a ground wire Figure 20 pos 3 connecting the compartment panel and the main ICon Pro unit DO NOT disconnect it 3 Pull up the two yellow locking levers Figure 20 p...

Страница 28: ...ure 21 pos 4 10 Turn the two knobs on the compartment panel Figure 21 pos 5 clockwise until the panel is locked 7 3 Recommended additional cleaning Keep the unit clean by wiping it with a dry cloth Do...

Страница 29: ...Con Pro software measures the operating time of each lamp in the neutralization chamber The total operating time is the indicator of the necessity of lamp replacement for service technicians only The...

Страница 30: ...us menu and follow the instructions as stated in 6 4 7 Status menu The ICon Pro sounds an alarm and the red LED indicator on the right side of the control panel is lit Panel s of filter compartment s...

Страница 31: ...ibly At the end of life the ICon Pro still contains valuable resources and needs to be disposed of according to your local laws and regulations regarding recycling of electrical equipment Before dispo...

Страница 32: ...ter life H14 average up to 24 months with 24 7 operation depends on PM contamination level PM particle filtration at 0 3 H14 99 999 VOC reduction TVOC 95 97 Microbiological contamination reduction lev...

Страница 33: ...33 10 2CE certificate...

Отзывы: