DC Inverter Air
4)
Description of Address DIP
a.
Capacity of Outdoor Unit (Model DIP) (14)
SW410
Model(HP)(BTU)(*100W)
SW410
(
8‐1
)
1
TCA‐36HRA/DV
0100 0000
2
TCA‐48HRA/DV3
0011 0000
3
TCA‐60HRA/DV3
0000 0000
Note: 1 –ON; 0 ‐ OFF
.
b.Piping Length DIP of Outdoor Unit (20) SW411:
SW411
(
4——1
)
1
Long
0000
piping
2
Short
0001
piping
Note: 1 –ON; 0 ‐ OFF
.
c.Capacity of Outdoor Unit (Model DIP) (14) SW1
Model(HP)(BTU)(*100W)
SW 1
(
4‐1
)
1
TCA‐18HRA/DVO
1111
2
TCA‐24HRA/DVO
0111
3.3 TCA‐48/60HRA /DV3 Electric Control Box (ECB)
1)
ECB Structure of Outdoor Unit
1—
Compressor drive module of outdoor unit;
2—
Main control panel of outdoor unit;
3—
Power supply terminal block of outdoor unit;
89
/
113
Содержание TCA-18HRA/DVO
Страница 1: ...Technical Manual for DC Inverter Air Conditioner 1 113...
Страница 13: ...DC Inverter Air 1 4 Electrical Wiring Diagram 13 113...
Страница 14: ...DC Inverter Air 1 5 Air Velocity and Temperature Distributions Airflow velocity 14 113...
Страница 22: ...DC Inverter Air 22 113...
Страница 28: ...DC Inverter Air 2 3 Service Space 2 4 Wiring Diagrams 28 113...
Страница 41: ...DC Inverter Air 3 2 Wirin g Diagra ms 41 113...
Страница 42: ...DC Inverter Air A irflow velo city Discharge angle 60 FLOOR 42 113...
Страница 43: ...DC Inverter Air Airflow velocity Temperature 43 113...
Страница 64: ...DC Inverter Air 7 2 Electrical Wiring Diagram 2 1 TCA 36HRA DV 64 113...
Страница 65: ...DC Inverter Air 2 2 TCA 48H RA DV3 TCA 60HRA DV3 65 113...
Страница 66: ...DC Inverter Air 2 2TCA 18HRA DVO TC A 24HRA DVO 66 113...
Страница 82: ...DC Inverter Air 82 113...