![TCL PDP42U3H Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/tcl/pdp42u3h/pdp42u3h_service-manual_4137502020.webp)
and GCUT-11K, set the reading of the color analyzer to x=0.265±0.005,
y=0.280±.0.005.
2)
Then measure the white side of the screen where the luminance is 100±5nit. By
changing the value of GGAIN-11 and RGAIN-11, set the reading of the color analyzer
to x=0.265±0.005, y=0.280±.0.005.
3)
Repeat step 1) & 2) until you can get the correct reading for both black and white
sides.
4)
Press RECALL button to quit.
ii. Adjustment of White balance under AV mode
1.
Receive the black/white pattern.
2.
Press “PICTURE” key to select STANDARD mode.
3.
Adjustment of Warm temperature( 9300K)
1)
Set BCUT-9K3 to 240, BGAIN-93 to 100. Use a color analyzer to measure the black
side of the screen (the scale where the luminance is about 5±1nit). Change the value
of RCUT-9K3 and GCUT-9K3 until the reading of the color analyzer to
x=0.284±0.005, y=0.299±0.005.
2)
Then measure the white side of the screen (the scale where the luminance is
100±5nit). By changing the value of GGAIN-93 and BGAIN-93, set the reading of the
color analyzer to x=0.284±0.005, y=0.299±0.005.
3)
Repeat 1) & 2) until you can get the correct reading for both black and white sides.
4.
Adjustment of Cool temperature(11000K)
1)
Set BCUT-11K to 245, BGAIN-11 to 100. Use a color analyzer to measure the black
side of the screen (the scale where the luminance is about 5±1nit). By changing the
value of RCUT-11K and GCUT-11K, set the reading of the color analyzer to
x=0.265±0.005, y=0.280±.0.005.
2)
Then measure the white side of the screen (the scale where the luminance is
100±5nit). By changing the value of GGAIN-11 and RGAIN-11, set the reading of the
color analyzer to x=0.265±0.005, y=0.280±.0.005.
3)
Repeat 1) & 2) until you can get the correct reading for both black and white sides.
4)
Press RECALL button to quit.
iii. Adjustment of White balance under YPbPr mode
1. Apply the 10 Gray-scale pattern to YPbPr.
2. Press “PICTURE” key to select STANDARD mode.
3. Adjustment of Warm temperature (9300K)
1)
Set BCUT-9K3 to 240, BGAIN-93 to 100. Use a color analyzer to measure the black
side of the screen(the scale where the luminance is About 5±1nit ). Change the value of
RCUT-9K3 and GCUT-9K3 until the reading of the color analyzer to x=0.284±0.005,
y=0.299±0.005.
2)
Then measure the white side of the screen. By changing the value of GGAIN-93 and
BGAIN-93, set the reading of the color analyzer to x=0.284±0.005, y=0.299±0.005.
3)
Repeat 1) & 2) until you can get the correct reading for both black and white sides.
4. Adjustment of Cool temperature (11000K)
1)
Set BCUT-11K to 245, BGAIN-11K to 100. Use a color analyzer to measure the black
side of the screen. By changing the value of RCUT-11K and GCUT-11K, set the reading of
the color analyzer to x=0.265±0.005, y=0.280±.0.005.
2)
Then measure the white side of the screen. By changing the value of GGAIN-11 and
RGAIN-11, set the reading of the color analyzer to x=0.265±0.005, y=0.280±.0.005.
3)
Repeat 1) & 2) until you can get the correct reading for both black and white sides.
4)
Press RECALL button to quit.
20