Test and Alignment Specification for MT5331 Series (v0 91)
Page 15 of 26
Area
RU (俄罗斯)
White Balance
Default
Project Name
Bom No.
COOL
NORMAL
WARM
COOL
NORMAL
WARM
Energy
Efficiency
L32E5300(俄罗斯)
H3-32E53T4-AACA0AA 270,290 280,300 315,335 .-3,0,9 128,128,128 16,0,-27
L39E5300F(俄罗斯) H3-39E53U3-UR1A0AA 260,280 270,288 305,325 .-3,0,9 137,128,128 16,0,-27
L28T3540(俄罗斯)
H3-28T354NKI-SC0
275,289 285,298 320,335 -5,0,12
130,128,138 12,0,-20
Cloning
To operate master/golden clone and reuse it further on demand, please to follow below Cloning SOP:
Cloning Procedure
for MT5531 Series (v1.00).pdf
All underused BIN image files need to be used strictly with MT5531 SoC platform as depending on SW
structure.
Other faster access methods via UART/IR commands
are available on enclosed SIACP requirements (rev.
v5.9).
2.4. High Pot. and Insulating Resistance Tests
At the end of the process, a
“High Voltage” and an “Insulating Resistance” tests are required to fulfil Safety
Electrical requirements (CEI 65065).
High Voltage Withstanding requirements
Insulating Resistance requirements
-
“Voltage”
3500
VAC
-
“Voltage”
500 VDC
-
“Max Leakage Current”
10 mA
-
“Threshold Min”
4M Ω
-
“Test Time”
5 sec
-
“Test Time”
3 sec
2.5. SHOP-END Test
At final process stage, it’s necessary to perform “
Reset shop
” before any packing to leave Factory mode and
restore User default presets.
This function is accessible by selecting
“
Factory menu
Reset Shop
”, then pressing RCU “
OK/
►” key. Other
faster methods via UART/IR commands are available on enclosed SIACP requirements (rev. v5.9).
“ResetShop” presets should follow “
MT5531_EU_OOB_MenuSetting_step1_Base_01.doc
” document.
Note:
A password might be required in case of Parental Control function is locked, use default “
1234
” password
or “
0423
” super password to clean-up existing ones if forgotten.