10
PEQ 3000 User Manual
5.3 Meters
The PPM meters (Peak Program Meters) at the far right include a very accurate
Peak-Hold function.
CAUTION: You must ensure that no peaks exceed 0dBFS. These peaks will be
shown in red for a short time, before decaying. Keep an eye on them, and do
something about it if you see them.
• •
Use the MASTER output gain control to adjust the levels if required
Input L/R
Output
Peaks have
reached
maximum
Enlarged view of the
top of the meter
Peaks
Lock
(gain is the
same value
for all presets)
Output Gain
5.4 EQ filters
In the PEQ 3000, all 12 (+12) bands are equally flexible, and each can be selected
from: Lo Cut, Lo Shelf, Bell, Hi Shelf, and Hi Cut. This way you do not need to
remember which band types are already in use, you can just go ahead adjusting.
Common features are:
• •
FREQ: The Frequency range goes from 2 Hz to 22 kHz. Note that
although the graphical horizontal axis limits the setting from 18 Hz to
20 kHz, settings outside this range can be set with the FREQ control
• •
GAIN (Bells and Shelves): There is continuous adjustment of boost and
cut from + 16 dB to - 16 dB, with a 0 dB center
• •
All bands can be individually switched on or off, or removed
5.4.1 Bell
Band In
Width
Narrow
Frequency
Gain
Band In
Width
Wide
Band
Bypass
•
•
FREQ: The circular frequency control dial adjusts the EQ band frequency
from 2 Hz to 22 kHz
• •
GAIN: There is continuous adjustment of boost and cut from + 16 dB
to - 16 dB, with a 0 dB center
• •
WIDTH: Adjusts the EQ band bandwidth in the range 0.1 to 5.3 Octave.
This allows for very wide or narrow range adjustments and problem
solving. The default width for an added band is 1.5 Octave.