![TC Electronic SYSTEM 6000 MKII Скачать руководство пользователя страница 30](http://html2.mh-extra.com/html/tc-electronic/system-6000-mkii/system-6000-mkii_operation-manual_3846320030.webp)
30
FRAME SYSTEM - MAIN
Single precision:
FADER 1
MIDI CC
70 Sound Controller 1
FADER 2
MIDI CC
71 Sound Controller 2
FADER 3
MIDI CC
72 Sound Controller 3
FADER 4
MIDI CC
73 Sound Controller 4
FADER 5
MIDI CC
74 Sound Controller 5
FADER 6
MIDI CC
75 Sound Controller 6
Double precision, LSB:
(Note that both LSB and MSB must be sent for double precision)
FADER 1
MIDI CC
48 General Purpose Controller #1
FADER 2
MIDI CC
49 General Purpose Controller #2
FADER 3
MIDI CC
50 General Purpose Controller #3
FADER 4
MIDI CC
51 General Purpose Controller #4
FADER 5
MIDI CC
52 Undefined
FADER 6
MIDI CC
53 Undefined
Double precision, MSB
(Note that both LSB and MSB must be sent for double precision)
FADER 1
MIDI CC
16 General Purpose Controller #1
FADER 2
MIDI CC
17 General Purpose Controller #2
FADER 3
MIDI CC
18 General Purpose Controller #3
FADER 4
MIDI CC
19 General Purpose Controller #4
FADER 5
MIDI CC 20 Undefined
FADER 6
MIDI CC
21 Undefined
External MIDI Control - of Fader Parameters
From software version 2.5, all fader assignable parameters can be remote controlled via MIDI Control Change Messages.
To be able to control Faders you must create a dedicated Fader User Group holding these parameters. Page 20 in this
manual section explains how to create User Fader Groups.
Single Precision - Double Precision
We support both single (7bit) and double precision (14 bit) Controller Data, but you should notice that best resolution is
achieved using 14 bit Controller Data. By controlling parameters with Single precision you will be able to control in 128
steps for a complete parameter range. For most applications this will be quite fine and this is also the precision most
external controllers and especially sequencers support. This is called 7 bit precision.
However, System 6000 supports the 14 bit precision standard that has a considerably higher resolution: 128x128=16384
steps.
To achieve this resolution via an external fader control the external controlling device must be able to handle two
controllers at the same time on the same MIDI channel. The scheme below shows which controllers to assign to which
Faders for both Single Precision and Double Precision situations.
MSB value indicates the actual double parameter change. So sending a LSB will not change
the value, but only cache this value for later use when receiving the MSB part.
The LSB must therefore be sent before the MSB.