______________________________________________________________________________________________________________________________________________________________________________
__________________
TC Electronic A/S
Finalizer Express Service manual
page 4
Quick Trouble Shooting
Use this table to solve problems or find out what to do next.
Symptom
Comments / Action:
Analog in/out fails
Try with other cables or read section "Built-in Test program". Note: When analog in/out is connected to unbalanced equipment, XLR
pin 3 must be connected to pin 1.
Note: If IC35 or IC36 or IC41 are defective, they should be replaced with type MC33079
Note: When running this test the input Meter must show -12dB for the channel on test.
Cannot turn power off with power switch at front
The switch must be pressed for at least 1 second to turn off power. The delay provide unintended power off during recording.
Cannot run application software.
Enter the Software BOOT menu, by pressing the SYNC FROM button at power on.
Select the option "V" by use of the up and down arrow keys to check the application software. Press the FINALIZE SOFTCLIP key to
execute. If corrupted; load the application software again.
Or try to run the self test prom, see section "Built-in Test program".
Bad LED's, keys or Pots.
See section "Built-in Test program".
Digital or Midi in/out fails
Try with other cables or read section "Built-in Test program". Digitech pedals are incompatible.
External Control In fails
Try with other cables or read section "Built-in Test program".
Software Boot Menu
To access the Software Boot Menu; press the SYNC FROM button while powering on. An option letter will appear in the FINALIZE LED matrix. Use the Up and Down arrow buttons to
select between the options. To leave the Software Boot Menu; turn off the power.
Option
Description
L
Load Application or Boot software directly from PCMCIA card.
R
Master Reset. Run this command and all settings are reset! Press the FINALIZE SOFTCLIP button twice to execute.
A
Display BOOT version. Press the FINALIZE SOFTCLIP button to execute.
V
Display the Application software version. Press the FINALIZE SOFTCLIP button to execute.
n
Display the serial Number. Press the FINALIZE SOFTCLIP button to execute.
S
Starts the loaded software. Press the FINALIZE SOFTCLIP button to execute.
Содержание Finalizer Epress
Страница 1: ...Technical service manual Finalizer Epress...