Chapter 2 Installation
System Configuration
TC8619 Rev 1.1User Manual
2-4
2.7.2
Rear Panel
Figure 2-2 TC8619 Rear Panel LED Definitions
ALM (Alarm) LED
x
Solid: Latched alarm condition.
x
Flash: Unit detects errors or is in loopback
mode.
x
Off: Normal
condition.
RAI (Remote Alarm Indicator) LED
x
Flash: Unit detected RAI (
Yellow Alarm
).
x
Off: Normal
condition.
AIS (Alarm Indication Signal) LED
x
Flash: Unit detected AIS (
Blue Alarm
).
x
Off: Normal
condition.
LOS (Loss of Signal) LED
x
Solid: Valid T1/E1 signal is detected.
x
Flash: No T1/E1 signal is detected.
Dipswitch Configurations
SW1: LOCLB (Local Loopback)
x
Down (On): Enable T1/E1 loopback.
x
Up (Off):
Normal.
SW2: WRR (Weighted Round Robin Scheduling)
x
Down (On): Weighted Round Robin Scheduling
x
Up (Off):
Strict Priority Scheduling
SW3: INT CLK (Internal Clock)
x
Down (On): Enable internal timing mode.
x
Up (Off):
Enable RX loop timing mode.
SW4: B8ZS / HDB3 (Line Code)
x
Down (On): B8ZS (T1) / HDB3 (E1)
x
Up (Off):
AMI
SW5: DIS ALM (Disable Alarm)
x
Down (On): Disable alarm buzzer and dry contact.
x
Up (Off):
Normal.
SW6, SW7, SW8: L1, L2, L3 (Line Build-Out)
L1
L2
L3
T1
Up
Up
Up
0 – 133 feet
Down
Up
Up
133 – 266 feet
Up
Down
Up
267 – 399 feet
Down
Down
Up
400 – 533 feet
Up
Up
Down
534 – 655 feet
Down
Up
Down
-7.5dB CSU
Up
Down
Down
-15dB CSU
Down
Down
Down
-22.5dB CSU
L1
L2
L3
E1
Up
Up
Up
75 ohm Normal
Down
Up
Up
120 ohm Normal
Up
Up
Down
75 ohm High Loss
Down
Up
Down
120 ohm High Loss
Alarm Relay
NO (Normal Open)
x
Open: When power is on, and alarm is off.
x
Close: When power is off, or alarm is on.
NC (Normal Close)
x
Close: When power is on, and alarm is off.
x
Open: When power is off, or alarm is on.