background image

TC3005

(LED/ELED/LASER)

User's Manual

Rev. 3.0

−3−

7.

7.

7.

7.

7.

Installation

Installation

Installation

Installation

Installation

Figure 3.  Installation Diagram for Dual TC3005 Application

Figure 3.  Installation Diagram for Dual TC3005 Application

Figure 3.  Installation Diagram for Dual TC3005 Application

Figure 3.  Installation Diagram for Dual TC3005 Application

Figure 3.  Installation Diagram for Dual TC3005 Application

Figure 4.  Installation Diagram for Single TC3005 Application

Figure 4.  Installation Diagram for Single TC3005 Application

Figure 4.  Installation Diagram for Single TC3005 Application

Figure 4.  Installation Diagram for Single TC3005 Application

Figure 4.  Installation Diagram for Single TC3005 Application

6.

6.

6.

6.

6.

Dry Contact Relay Alarm

Dry Contact Relay Alarm

Dry Contact Relay Alarm

Dry Contact Relay Alarm

Dry Contact Relay Alarm

A terminal block connector on the rear panel (labeled
"ALARM") provides for the dry contact relay alarm (see Figure
2).  Normally in the OPEN position, the loss of either optic signal
will trigger an alarm condition and force the switch to the
CLOSED position.  This relay can be used in conjunction with
an external device to monitor the condition of the fiber optic
links.  Note: If SW4 (DISALM) on the front panel is in the Down
position, the audio buzzer will not sound and the dry contact
relay will not activate.

SM Tx

SM Rx

Single Mode

fiber optic cable

TC3005

Fiber Optic Mode Converter

Multimode

850nm/1300nm

TRANSCEIVER

Rx

Tx

MM Tx

MM Rx

Multimode
fiber optic

cable

MM Rx

MM Tx

TC3005

Fiber Optic Mode Converter

Multimode

850nm/1300nm

TRANSCEIVER

Rx

Tx

SM Rx

SM Tx

Multimode
fiber optic

cable

SM Tx

SM Rx

Single Mode

fiber optic

cable

TC3005

Fiber Optic Mode Converter

Multimode

850nm/1300nm

TRANSCEIVER

Rx

Tx

MM Tx

MM Rx

Multimode
fiber optic

cable

Single Mode

1300nm/1550nm

TRANSCEIVER

Tx

Rx

Dry Contact Relay

Alarm Switch

To remote alarm status indicator

Max switch voltage: 100VDC
Switch current: 0.5Amp
Max carry current: 1.2Amp
Contact resistance: 0.2Ohm

Reply switch specifications

Содержание TC3005

Страница 1: ...550nm SingleMode 9 125µm up to 110km Wavelength Wavelength Wavelength Wavelength Wavelength Note Any two wavelength combinations are available on each unit 850nmMultimode LED 1310nmMultimode LED 1310nmSingleMode ELED LASER 1550nmSingleMode ELED LASER Connector Connector Connector Connector Connector ST FC or SC Launch power sensitivity and distance are listed for reference only These numbers may v...

Страница 2: ...tors MMRX Solidly lit indicates a valid optical signal is received at the MM receiver it is above sensitivity threshold Off indicates the optical signal at the MM RX is not present lost bursty or questionable not valid Verify that the user s Multimode device optical wavelength matches that of the TC3005 units Verify the integrity of the Multimode fiber cables and connections Single Mode Optic Sign...

Страница 3: ... for the dry contact relay alarm see Figure 2 Normally in the OPEN position the loss of either optic signal will trigger an alarm condition and force the switch to the CLOSED position This relay can be used in conjunction with an external device to monitor the condition of the fiber optic links Note If SW4 DISALM on the front panel is in the Down position the audio buzzer will not sound and the dr...

Страница 4: ...ion permanently insert a 5dB or 10dB in line attenuator into the problem link In line attenuators can be purchased from Metrotek at 727 547 8307 The part numbers are Description Description Description Description Description ST 5dB ST 5dB ST 5dB ST 5dB ST 5dB ST 10dB ST 10dB ST 10dB ST 10dB ST 10dB FC 5dB FC 5dB FC 5dB FC 5dB FC 5dB FC 10dB FC 10dB FC 10dB FC 10dB FC 10dB PartNumber PartNumber Pa...

Страница 5: ...all bear the risk of loss until all goods authorized to be returned are delivered to TC Communications Inc TC Communications Inc shall not be liable for any inspection packing or labor costs in connection with the return of goods In the event that TC Communications Inc breaches its obligation of warranty the sole and exclusive remedy of the Buyer is limited to replacement repair or credit of the p...