RACK MOUNT INSTRUCTIONS

Rack Mounting

Attach the supplied mounting
brackets to the Hub chassis
using the supplied screws.

Note that the brackets allow
installation with the front or rear
facing out. 

Care should be taken when
installing in a rack environment,
specifically:

Elevated Operating Ambient

- If the

NV-ER1808i is installed in a closed or
multi-unit rack assembly, the operating
ambient temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given to installing the 
equipment in an environment compatible with the maximum ambient temperature does not exceed 50°C (122°F). 

Reduced Air Flow

- Installation of the NV-ER1816i in a rack should be such that the amount of air flow required for

safe operation of the equipment is not compromised. 

Mechanical Loading

- Mounting of the equipment in the rack should be such that a hazardous condition is not

achieved due to uneven mechanical loading.

Mains Circuit Overloading

- Consideration should be given to the connection of the equipment to the supply 

circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring.
Appropriate consideration of equipment nameplate ratings should be used when addressing this concern.

Reliable Earthing

- Reliable earthing of rack-mounted equipment should be maintained. Particular attention

should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).

Wall Mounting

For wall-mount installations, attach the supplied mounting brackets to opposite corners of the Hub chassis using
the supplied screws.

Attach the brackets to the wall using wood screws (not supplied).

Table Mounting

For table-mount
installations, attach
the four rubber feet
(supplied) to the 
bottom of the 
chassis.

OUTPUTS:  56VDC       1AMP MAX. PER PORT

(no anal

og 
/ no ether

net)

USE ON

LY 

WITH A 250V FUSE

Auxiliary

Join

Link

10/100/1000

10/100/1000

Main

Power

Auxiliary

Join

Link

10/100/1000

10/100/1000

Main

Powe

r

Auxiliary

Join

Link

10/100/1000

10/100/1000

Main

Power

Page 4 of 25

Network Video Technologies

(+1) 650.462.8100 • +44 (0) 208 977-6614

nvt.com • [email protected]

Содержание NV-ER1816i

Страница 1: ...o not install the unit in an environment where the operating ambient temperature exceeds 185 F 85 C The ventila tion should not be impeded by covering the unit with items such as newspapers table clot...

Страница 2: ...6 VDC power supply can be optionally augmented by an external 250 watt auxiliary power supply supporting redundancy and or higher power applications The NV ER1816i is backed by NVT s award winning cus...

Страница 3: ...Power LEDs on both Transceivers will return to a steady on condition and their green TBus Link LEDs will illuminate indicating a successful Join One TBus Link LED will remain on solid The other may wi...

Страница 4: ...deration should be given to the connection of the equipment to the supply circuit and the effect that overloading of the circuits might have on overcurrent protection and supply wiring Appropriate con...

Страница 5: ...plied mounting brackets to the TBus Hub chassis using the supplied screws Note that the brackets allow the Hub to be mounted with either the front or rear facing out Connect the TBus wiring from as ma...

Страница 6: ...ans that multiple remote camera end transmitters may be connected together to one receiver at the control room Wire may be star topology daisy chained or any combination TBus supports virtually any ty...

Страница 7: ...rt that is sent in the direction of the camera That Report is monitored and passed on by switches and routers within the network That monitoring is called IGMP Snooping These switches and routers each...

Страница 8: ...we have up to 13V of allowable voltage drop on the wire The voltage will dip in proportion to the remote camera load The graph below shows what PoE power distances are supported for various loads and...

Страница 9: ...com Network Video Technologies 1 650 462 8100 44 0 208 977 6614 nvt com info nvt com 1 000 ft 700 ft 500 ft 10 000 ft 7 000 ft 5 000 ft 3 000 ft 2 000 ft 100 ft 300 ft 200 ft 20 000 ft 1 000 m 700 m 5...

Страница 10: ...y wire any wire IP Camera NV ET1801 Cat5 IP Camera NV ET1801 Cat5 IP Camera NV ET1801 Cat5 IP Camera NV ET1801 Figure 5 Sixteen Cameras Star Topology 328ft 100m Cat5 SFP Port Hybrid DVR or NVR LAN WAN...

Страница 11: ...t 100m IP Cameras Eight NV ET1804s Eight NV ET1801s NV ER1816i NV PS56 250W 250W Auxiliary Power Supply 328ft 100m Cat5 Hybrid DVR or NVR LAN WAN Switch or Router SFP Port Network Video Technologies 1...

Страница 12: ...re 9 Mixed Media 328ft 100m Cat5 328ft 100m Cat5 Hybrid DVR or NVR LAN WAN Switch or Router UTP wire Coax Coax IP Camera NV ET1801 NV ER1816i NV ER1816i NV ER1816i 328ft 100m Cat5 Hybrid DVR or NVR LA...

Страница 13: ...ing Cat5 328ft 100m RJ45 Cat5 Hybrid DVR or NVR LAN WAN Switch or Router Laptop for diagnostics any wire IP Camera NV ET1801 NV ER1816i Cat5 328ft 100m RJ45 any wire IP Camera NV ET1801 NV ER1816i Fig...

Страница 14: ...rs Each power supply within a multi output unit is intended to support one and only one TBus Hub WARNING For safety never use more than one Auxiliary Power Supply with each NV ER1816i Receiver Hub DUA...

Страница 15: ...Open your web browser and point it to https 192 168 254 1 which is the factory default address of the NV ER1816i Hub For best results please use the latest version of Internet Explorer with the latest...

Страница 16: ...Submit The NV ER1816i supports one username and password 1 NV ER1816 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 Auxiliary Join Link 10 100 1000 10 100 1000 Main Power 16 Port Ethernet Receiver JoinButton F...

Страница 17: ...on a naming description field is available The hub will remember each entered description associated with every transmitter MAC address This memory is non volatile TBus devices must be Joined to commu...

Страница 18: ...re 22 Power Page Network Video Technologies Security Industry Leader TBus Sixteen Port Ethernet Receiver Model NV ER1816i HW Rev A FW rev 1 2 IP Address 192 168 254 0 Channel 1 Watts 0 50 45 40 35 30...

Страница 19: ...iver Network Video Technologies Security Industry Leader TBus Sixteen Port Ethernet Receiver Model NV ER1816i HW Rev A FW rev 1 2 IP Address 192 168 254 1 Figure 23 Monitor Page Rear Parking Lot Camer...

Страница 20: ...lick Restore Firmware Upgrade Firmware upgrades will be available from time to time on the nvt com website For security most CCTV LANs are closed not accessible to the internet To avoid this issue fir...

Страница 21: ...unable to perform this Switch configuration then NVT recommends you instead manually configure the NV ER1816i to generate an IGMP Report for each multicast camera See below If your network has no IGMP...

Страница 22: ...Transmitter Netw ork Video Technologies Link Data 1 PoE Data 4 PoE Data 3 PoE Data 2 PoE 50W PoE n o Eth er ne t no an alog Quality 10 100 PoE 56VDC JOIN LINK NV ET1804 Ethernet Transmitter Netw ork...

Страница 23: ...NV PS56 60W 56V DC power supply 60 watts with IEC line cord NV PS56 90W 56V DC power supply 90 watts with IEC line cord Do not use with NV ER1816i NV BNCT BNC T adaptor NV EC4BNC 1 4 BNC splitter ada...

Страница 24: ...ng connectors and rack ears Shipping weight 10 37 lbs 4 70 Kg Operating storage temperature 40 F to 185 F 40 C to 85 C 20 to 85 relative humidity non condensing Generated heat Under full 220W load hub...

Страница 25: ...obligation on the part of NVT with respect to any of the products In the event that any of the products is dam aged altered or modified without the express written consent of NVT any warranty for tho...

Отзывы: