13
Battery bank 2 voltage (V)
Shows the voltage of battery bank 2 (connected to the +B2
input). This value will only be shown when the +B2 input is
configured as a second battery input (see Function F2.0).
Battery bank 3 voltage (V)
Shows the voltage of battery bank 3 (connected to the +B3
input). This value will only be shown when the +B3 input is
configured as a third battery input (see Function F3.0).
Main battery current (A)
Shows the current flowing in- or out of the main battery. A
negative sign indicates a discharge current and a positive sign
a charge current.
Main battery power (W)
Shows the power draw from the main battery (negative sign)
or the power flow into the battery (positive sign). This reading
is turned off by default and can be turned on in Function F9.2.
Main battery Amp-hours (Ah)
The amount of Amp-hours discharged from the battery. This
reading is turned off by default and can be turned on in
Function F9.3.
Main battery time remaining
(h:m)
Shows how much time is left under the present load, before
the battery is empty.
Содержание Expert Modular
Страница 2: ...2...
Страница 4: ...4 English Page 5 Nederlands Pagina 32 Deutsch Seite 59 Francais Page 88 Espa ol P gina 117...
Страница 5: ...5 Owner s manual...
Страница 35: ...35 Gebruiksaanwijzing...
Страница 65: ...65 Bedienerhandbuch...
Страница 97: ...97 Mode d emploi...
Страница 129: ...129 Manual del propietario...
Страница 162: ...www tbs electronics com TBS Electronics BV De Marowijne 3 1689AR Zwaag The Netherlands E Mod TBS Manual Web Rev2endfs...