background image

 
 

TBS Installation Manual 

 

2D IRON & 3D AIR

 

 

TBS 2D IRON 3D AIR Mounting and Installation Guideline    

• 

   TBS-056-057    

• 

   Rev 09-2023

 

page 4 of 21

 

 

2

 

Legal and Safety Instructions 

 

Allowed Applications 

TBS  products  are  not  designed,  authorized,  or  warranted  to  be  suitable  for  use  in  medical,  military, 
aircraft,  space  or  life  support  equipment,  nor  in  applications  where  failure  or  malfunction  of  a  TBS 
product  can  reasonably  be  expected  to  result  in  personal  injury,  death  or  severe  property  or 
environmental  damage.  TBS  accepts  no  liability  for  inclusion  and/or  use  of  TBS  products  in  such 
applications. 
 

 

Inspection of goods received 

If the packaging or product has been damaged in transport, or should you suspect that it may have a 
fault, the product must not be put into service. In this case, contact your TBS company representative. 
 
 

Installation and Servicing 

Installation,  setup,  and  servicing  of  our  appliances  must  only  be  carried  out  by  suitably  trained 
personnel.  

 

Installation and electrical connections must only be made by correspondingly qualified specialists. 
The relevant national Electrical Engineers construction regulations must be observed.  

 

Setup and servicing must only be made by persons who have the know how to do so e.g., by 
reading the respective TBS manuals or attending TBS trainings / webinars.  

 
When not otherwise stated, the following safety instructions apply:  

 

Installation and servicing of our appliances must be carried out when disconnected from the 
power supply, in particular appliances that are normally supplied by low-voltage current.  

 

It is prohibited to alter the device or to remove protective shields and covers.  

 

Do not attempt to repair an appliance after a defect, failure, or damage, or to put it back into 
operation again. Please contact in such case your TBS company representative or the TBS hotline.  

 
If there are still some points on which you are not entirely clear, please do not take a chance. All queries 
can be clarified by your TBS company representative, or by ringing the TBS hotline.  
 

WASTE DISPOSAL: 

This symbol means do not dispose of your product with your other 

household waste. Instead, you should protect the environment and human health by handing 
over the marked equipment to a designated recycling facility or an electrical and electronic 
waste collection point. 

 
 

 

Disclaimers 

TBS accepts no responsibility for any injuries or damage caused as a result of improper use.  

Information in this document is believed to be accurate and reliable. However, TBS does not give any 
representations  or  warranties,  expressed  or  implied,  as  to  the  accuracy  or  completeness  of  such 
information and shall have no liability for the consequences of use of such information. 

Should you discover any fault with  the product or in its documentation, or have any suggestions for 
improvement, please confidently approach your TBS company representative or TBS hotline.  

TBS  reserves  the  right  to  make  changes  to  information  published  in  this  document  at  any  time  and 
without notice.  

 

 

Содержание 2D IRON

Страница 1: ...of this document is always available at https cloud1 tbs biometrics com index php s IcgqtcdZXJVBrzA Revision Author New content Oct 22 2021 AG TO First Release April 13 2022 AG TO Minor updates Aug 18...

Страница 2: ...3 Mounting Instructions 9 4 3 1 Preparation 9 4 3 2 Wall Mount Box 9 4 3 3 Heavy Duty Box IP65 10 4 3 4 Flush Mount Box IP54 11 5 Power and Signal Wiring 12 5 1 Electrical Connection and Cabling 12 5...

Страница 3: ...TBS 056 ICL WM HID PROX TBS 056 PRO WM Legic Mifare Classic or Desfire TBS 056 LEM WM Wall Mount Heavy Duty IP65 none TBS 056 STD HD HID iClass TBS 056 ICL HD HID PROX TBS 056 PRO HD Legic Mifare Cla...

Страница 4: ...of our appliances must be carried out when disconnected from the power supply in particular appliances that are normally supplied by low voltage current It is prohibited to alter the device or to remo...

Страница 5: ...nditions 1 the device may not cause harmful interference and 2 the device must accept any interference received including interference that may cause undesired operation Changes or modifications not e...

Страница 6: ...ng temperature 20 to 60 C Relative humidity 10 to 90 Outdoor device use is not compliant with UL294 In the case of 3D AIR strong ambient light and or direct light into the sensor of the terminal shoul...

Страница 7: ...ame for all three mounting variants wall mount heavy duty wall mount flush mount 4 2 1 Opening the Device IMPORTANT Always disconnect power supply before opening terminals Unlock 1 Use Allen wrench si...

Страница 8: ...Allen wrench size 3 to lock front part to back cover Screw in fully and turn back half a turn IMPORTANT To avoid destruction and electrical shorts please ensure no cable or metal parts press against t...

Страница 9: ...the installation for the passage of cables Make sure that the installation wall is completely flat to allow a nice and proper mounting TBS provides very accurately manufactured enclosures that only fi...

Страница 10: ...he heavy duty variant Four 4 5mm screws and fitting raw plugs suitable for the wall material not included One screwdriver appropriate to drive the above screws One drill with a drill bit of an appropr...

Страница 11: ...t a rectangular shape with dimensions of 204 x 127 mm height x width as in the two pictures These dimensions include 1 5 mm air spacing all around the box It is not required to cut the precise box dim...

Страница 12: ...of the wire terminal before removing the cable to unlock the latch NOTE Removing cables with force from the wire terminal may damage the wire terminal or the board Unlock the latches before removing...

Страница 13: ...wer supply to the terminal can also be provided by Ethernet using RJ45 connection Power over Ethernet IEEE802 3af compliant TBS recommends using an ethernet cable of Cat5e standard or higher The termi...

Страница 14: ...age to the input line For each input independently the desired operating mode is selected by inserting or removing a resistor to a respective GP IN pull up resistor socket on the mainboard Resistor is...

Страница 15: ...activate security access equipment For such TBS offers two dedicated controllers 5 6 Connecting TBS Controllers For various applications TBS Terminals need to be connected with external controllers e...

Страница 16: ...pen Closes when the tamper switch is activated C Common 30 VDC 1A 220 VDC 0 14 A 120 VDC 0 25 A 250 VAC 0 12 A NC Normally Closed Opens when the tamper switch is activated A recommended way of utilizi...

Страница 17: ...ring regular usage Special tests to check for correct functioning are therefore not required TBS recommends checking the integrity of the sensor surfaces and openings of the terminals at least every 6...

Страница 18: ...unication with reader failed Shutdown and re power the device 423 RFID card reading error 430 Unknown Relay GPIO error 431 Relay GPIO communication error 440 General problem with external verification...

Страница 19: ...8 HTTPS communication channel to BME server and Device Control Center DCC No Yes Enrollment API 8281 8282 8284 HTTP S communication channel between enrollment components Yes 2 No 8283 MQTT Enrollment...

Страница 20: ...T Enrollment PC WE channel 1 80 443 HTTP S communication channel to WE server and Device Control Center DCC No Yes Series12 terminal WebEdition 1 80 443 HTTP S communication channel to WE server and D...

Страница 21: ...istered TBS Partners TBS System Requirements Permanent link https cloud1 tbs biometrics com index php s q8V3hzrLyR0Mnyg Summarizes the prerequisites a site needs to offer regarding server network to h...

Отзывы: